![CKD ABSODEX AX9000XS-U2 Instruction Manual Download Page 24](http://html1.mh-extra.com/html/ckd/absodex-ax9000xs-u2/absodex-ax9000xs-u2_instruction-manual_2611713024.webp)
3. CC-Link Communication Function
[SMF-2008-A]
– 3-11 –
iii)
End of setting
After the settings are normally entered, a completion screen is displayed.
Shutdown and restart the power after finishing configuration.
Settings for station No. and baud rate will take effect after the power has been restarted.
Fig. 3.7. Screen for end of setting
iv)
Error in setting
The following screen is displayed if there is an error in the station number setting.
Fig. 3.8. Warning screen at time of error setting of station number
If the system is initialized, CC-Link register settings will return to default settings. Set the
CC-Link register setting again after initializing the system.