[SM-206792-A/3]
−
32
−
SPECIFICATION
8
Example of same model Manifold
M3KA111-M5-7
Indicates 3KA1 manifold, 2-position single normal close B ports M5 top
porting, 7 stations,
Example of mixed manifold
Method of coding the contents of combination :
Indicate the number of the function-wise master valves (simplex) after the
normal Model No. indication when selecting the mixed manifold (code 8 in -).
After the Model No., clearly indicate the code of the required function (see
Table below) and the arrangement no. (carry out numbering up to the speci-
fied no. of stations, with the left side station as no. 1) as shown below
Code
Function
1
2-position single normal close(S10)
S10
2-pos. single normal close
2
2-position single normal close(S10)
S11
2-pos. single normal open
3
2-position single normal close(S10)
S20
2-pos. double
4
2-position double (S20)
MP
Masking plate
5
2-position double (S20)
6
2-position double (S20)
7
2-position single normal close(S10)
8
2-position single normal close(S10)
9
2-position single normal open(S11)
The method of indicating the manifold combination in the Model No. Indicating method for the above arrangements,
with port size M5 top porting
Model example
M3KA181-M5-9-
Enter the number.
If not in use, enter zero.
(S10
=
1to3,7,8 S20=4to6,S11
=
9)
When using more than 10 valves of the same Model No. in the mixed mani-
fold, specify the nos. of valves by using codes (alphabet)
Number of valves
10
11
12
13
14
15
16
17
18
19
20
Code (alphabet letters)
A
B
C
D
E
F
G
H
I
J
K
5
1
3
0
S10 S11 S20 MP