INSTALLATION AND USER INSTRUCTIONS

All instructions must be handed to user for safekeeping

Revision A - 08/05

Country(s) of destination - GB/IE

AFINA

SLIMLINE GAS FIRE

MULTIFLUE GAS FIRE

CK Fires Ltd. 1 Stour House, Clifford Park, Clifford Road, 

Stratford Upon Avon, CV37 8HW

Tel : 01789 290 999  Fax : 01789 290 998

Summary of Contents for Afina Multiflue

Page 1: ...must be handed to user for safekeeping Revision A 08 05 Country s of destination GB IE AFINA SLIMLINE GAS FIRE MULTIFLUE GAS FIRE CK Fires Ltd 1 Stour House Clifford Park Clifford Road Stratford Upon...

Page 2: ...led by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instru...

Page 3: ...before i installation a and u use o of t this a applianc ce This a applianc ce i is f free f from a any y a asbestos m material R Refrac ctories a and f fuelbed a are c construc cted from c ceramic c...

Page 4: ...flue must not vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appliance is installed into and the one venting the ga...

Page 5: ...um clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue Any type of fire surround used with this a...

Page 6: ...etary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional N Note The frame of the fire any back panel or other infill panels and the flue box mu...

Page 7: ...ommet supplied A small incision can now be made in the rubber to slip snugly around the outside of the supply pipe and sleeving Note D DO NOT install or use the appliance without this seal in place If...

Page 8: ...eplace openings Any sleeving should be sealed to the pipe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABLE FIX...

Page 9: ...refront will clear the supply route If the data control plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT C Coal e effect o opt...

Page 10: ...n not b be c crammed t together o or i inserted i into t the h holes in t the m matrix A A w well l laid o out g generously s spaced p pebble l layout w will g give t the best r results The pebbles m...

Page 11: ...with the appliance running If this is incorrect it will need to be reset by the gas supplier If the setting pressure is too low but the meter pressure is acceptable then a problem in the supply pipew...

Page 12: ...gas supply Ensure that the fire is fully cold before attempting service A suggested procedure for servicing is detailed below 1 Lay out the dust sheet and tools 2 Carefully remove the ceramic compone...

Page 13: ...the filter then the pipework and control should be thoroughly cleaned before re assembly REMOVING T THE F FIREBOX Remove the burner tray as described previously Protect the hearth from potential dama...

Page 14: ...or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant sectio...

Page 15: ...k click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten seconds N...

Page 16: ...sive build up of soot The frequency of service will depend on usage but MUST be carried out at least once annually Servicing must be carried out by a competent person such as a CORGI registered instal...