background image

 

ii 

 

 

CAUTION 

RISK OF ELECTRIC SHOCK DO NOT OPEN 

 

 

 

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, 

DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE 

PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

 

 

 

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the 
user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may 
be of sufficient magnitude to constitute a risk of electric shock to persons. 

 

The exclamation point within an equilateral triangle is intended to alert the user to the presence 
of important operating and maintenance (servicing) instructions in the literature accompanying 
the product. 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

READ BEFORE OPERATING EQUIPMENT 

This product was designed and manufactured to meet strict quality and safety standards. 

There are, however, some installation and operation precautions which you should be particularly aware of. 

1.

 

Read these instructions. 

2.

 

Keep these instructions. 

3.

 

Heed all warnings. 

4.

 

Follow all instructions. 

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with dry cloth. 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce 

heat. 

9.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. If the provided plug does not fit into 

your outlet, consult an electrician for replacement of the outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the 

point where they exit from the apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. 
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 

13.

 

Unplug this apparatus during lightning storms. 

14.

 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in 

any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the 
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 

 

 

Summary of Contents for CG800 H2 Series

Page 1: ...bility of the data contained in this publication however CityGrow Energy Systems Limited makes no representation warranty or guarantee in connection with this publication and hereby expressly disclaim...

Page 2: ...near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat...

Page 3: ...2xx CG800S4 CG800DMxx and CG800DM2xx 4 5 Wiring for CG800S2 CCP and CG800S4 CCP 6 6 Installation 7 7 Operation instruction 9 7 1 CG800S1xx CG800S2xx and CG800S4 9 7 2 CG800DMxx and CG800DM2xx 10 7 3 C...

Page 4: ...IEEE 802 15 4 3 2 4GHz radio frequency 4 CG800S1 S2 S4 DM lighting control 5 CG800S2 S4 CCP Open Close control for electric or motorized curtain and window blind 6 CG800xxH2 4 functions control 7 LED...

Page 5: ...the button plate Load terminals Control button Control Unit Rear View 1 2 3 4 Contacts for button plate Control Unit Front View Button Plate Rear View Frame Programming port Connector to control unit...

Page 6: ...ang Switch Load 1 Load 2 Load3 Load 4 CG800DM One Gang Dimmer Load 1 NC NC NC CG800DM2 Two Gang Dimmer Load 1 Load 2 NC NC CG800S2 CCP One Gang Curtain Control Switch Motor 1 Backward Motor 1 Forward...

Page 7: ...le damage to equipment WARNING Do not operate when any lamps removed or burned out replace any burned out lamps immediately use only transformers that incorporate thermal protection or fused primary w...

Page 8: ...5 Situation 1 Live Neutral and Load wires are ready at wall box Situation 2 Live and Load wires are ready at wall box Neutral wire is only ready at ceiling...

Page 9: ...6 5 Wiring for CG800S2 CCP and CG800S4 CCP...

Page 10: ...witch and disassemble the wiring STEP 3 Connect the main power cable to the Live and Neutral terminals and the load cable to the load terminals at the rear cabinet of the product STEP 4 Fasten the scr...

Page 11: ...correctly If the ON OFF Button does not function as expected please check the wiring connection again Notes Use Standard UK BS4662 wall box for installation It is recommended to embed the wall box wi...

Page 12: ...BUTTON 1 1 Cover BUTTON PLATE 2 4 5 3 Master Kitchen 2 Label LED Indicators 3 ON OFF Buttons 4 Programming Port 5 Reset Button Press ON OFF Button once to toggle between ON and OFF BRIGHT LED indicate...

Page 13: ...gramming Port 6 Reset Button Press the Dim Up Dim Down button ONCE to Toggle between ON and OFF LED FLASHING indicates that that the Button was pressed and dimming is in progress When the LED stopped...

Page 14: ...4 Reset Button 5 Programming Port Press the Open Close Button once to control the electric curtain Press the OPEN button to open the stopped electric curtain Press the CLOSE button to close the stoppe...

Page 15: ...Opening Closing time Please follow the instructions below to perform the Learning Mode function STEP 1 Press the CLOSE Button until the curtain is completely closed NOTE You may have to press the Butt...

Page 16: ...opened press and release any Button NOTE The duration of the Opening Closing time will be stored when a Button is pressed STEP 5 Use a pointed object to press the Reset Button again The learning mode...

Page 17: ...5 pin connector of the product and then plug the other end of the CG101UT5 cable into the mini USB end of the CG101UTC cable STEP 3 Plug the CG101UTC cable into the USB port of a PC which has been in...

Page 18: ...ammed and control up to 50 devices 3 The maximum load requirements for fluorescent CFL and LED loads may vary depends on the specific fixture and or bulb being used 4 CG800 dimmers are compatible with...

Page 19: ...ent CFL Per Gang 400W Max 24 pcs CFL 400W Max 24 pcs CFL 200W Max 12 pcs CFL 400W Dimmable CFL Max 20 pcs CFL 200W Dimmable CFL Max 20 pcs CFL N A LED GU10 Per Gang 200W 200W 100W 60W 30W N A LED MR16...