Mains Wire Installation and Termination
Install the mains cable or conduit in the entry provided as shown in Figure 2 on page 7. A liquid
tight cable grip is provided for use with suitable outdoor rated cable with diameter range of
.170”/4.3mm - .450”/11.4mm.
When cable is used, strip outer
jacket 6”/150mm.
The mains connection is a 3 pos. plug/socket type terminal block which may be disconnected for
ease of assembly. Strip insulation from individual
conductors .25”/7mm and terminate in the
provided screw terminal socket. Mains terminations are are marked on the unit.
DMX512 Wiring
The Multiverse Vero Transceiver is provided with a PCBA mount terminal block for DMX
connection (see illustration above). DMX Input / Output connections are marked on the unit.
Installing the Cover
The Multiverse Vero Transceiver has a two part cover, with the outer plastic cover connected to
the inner metal cover with a hinge. Install the metal inner cover using the eight provided 6-32 x
.375
” SS Truss Head Machine Screws. Hand install these screws until the screw threads are fully
engaged with the mating PEM Nut, then tighten to 4 inch pounds.
The outer cover is then closed and secured with the provided 8-
18 x .500” SS Thread Forming
Torx Button Head Security Screw, installed in the provided hole on the left side of the cover
assembly.
User Interface Screen
Upon power up, the Multiverse Vero Transceiver 900MHz/2.4GHz will boot into the main screen,
which displays the SHo
W ID and connection status. Pressing the “Up” or “Down” button will take
you to the universe selection screen.
Pressing “Enter” will select SHoW ID or universe for editing
and will commit the change when done.
SHoW ID on Tx screen SHoW ID on Rx screen Universe on Rx screen