31
Setting the width of module of two-dimensional barcode/ GS~w
[ASCII]
GS
~
w
n
m
I
[Decimal] 29
126
119
n
m
I
[Hexadecimal] 1D 7E 77 n
m I
[Parameter]
n = 0, 1
[Description]
●
The size of two-dimensional barcode modules can be specified with the value of ‘n’. The unit is dot.
n = 0: PDF417 module width specification
1: QR module width specification
●
For PDF417, module width and symbol column height can be specified.
m: Module width (01h to 08h)
I: Symbol column height (01h to 08h)
●
The symbol column height of PDF417 is internally converted into ‘(Module width) × (Symbol column height setting
value I)’.
●
For QR codes, only module width can be set. For QR code module width setting, skip parameter I.
m: Module width (01h to 0Fh)