— 33 —
(2)
TTL circuit (PE/RESET/FAULT)
Input (RESET)
The input signal level is TTL level.
“HIGH” level: 2.4 V MIN
“LOW” level: 0.4 V MAX
Output (RE/FAULT)
The output signal level is TTL level.
“HIGH” level: 2.4 V MIN
“LOW” level: 0.4 V MAX
5K
104
10K
RESET
(7406 compatible)
PE/FAULT
(HC05 compatible)
6.5 Error Detection
This printer detects the following communication errors in the data communication
of serial interface. When any error occurs, the printer converts (or may ignore in
some case) the data at the occurrence of the error to the characters set by the memory
switch and then prints the characters.
• Parity error
Parity error occurs when parity check is specified and parity is not observed in
the even and odd parity checks.
• Framing error
When space state detected on detection of stop bit.
• Overrun error
This error occurs when next data is transferred to receiving buffer though input
buffer is full of data.
RECEIVING CONTROL AND BUFFERING
This equipment controls, on receipt of print data, receiving (DTR Control) in one-word
unit. If the host disregards DTR and carries out data transmission at this time, over-
run of receiving data may be resulted. This state should be avoided on the host’s
responsibility. (The data discharging type host cannot follow this.)
Summary of Contents for CBM-920II
Page 1: ...DOT MATRIX PRINTER MODEL CBM920II User s Manual PAPER FEED ...
Page 53: ... 50 4 CP437 USA Std Europe 5 Katakana 6 CP858 Multilingual 7 CP860 Portuguese ...
Page 54: ... 51 8 CP863 Canadian French 9 CP865 Nordic 10 CP852 Eastern Europe 11 CP866 Russian ...
Page 55: ... 52 12 CP857 Turkish 13 WPC1252 Windows Latin1 14 CP864 Arabic 15 CP869 Greek ...
Page 57: ... 54 10 EXTERNAL DIMENSIONS ...