BD2-2860 User’s Manual
CITIZEN
54
ESC c5 n
[Function]
Enabling/Disabling Panel Switches
[Code]
<1B>H<63>H<35>H<n>
[Range]
{0 =< n =< FF} Data is described in Hex code.
[Outline]
Selecting the LF switch valid/invalid.
•
"n" is valid only in the lowest bit (n0).
•
"n" bit means the followings.
n0
Condition
0
LFSW valid.
1
LFSW invalid.
[Caution]
When the panel switch is disabled with this command, the LF switch is disabled. Therefore,
the paper cannot be fed by operating the LF switch.
[Default]
•
The initial value of n is "0".
[Sample Program]
LPRINT CHR$ (&H1B) + "c5" + CHR$ (0);
………
When enabling the LF switch
LPRINT CHR$ (&H1B) + "c5" + CHR$ (1);
………
When disabling the LF switch