background image

 

Remote Cycle-Timer Controller w/XLR 3 pin 25’ (7.6m)  

 

DMX Control on-board with in/out 

 

Power Cord 

 

Instruction booklet 

 

Extra fuse in fuse release holder 

 

2. Accessories 

 

 

CITC’s High Performance Fluid  (oil-based) (formerly Diffusion Fluid) 

 

P/N 150660 (available in gallon (3.8 liter) and 5-gal. (19 liter) cubitainer) 

 

Wireless Remote Control to 100’ (30m) Receiver & Sender (P/N 250010) 

 

StarHazer II

TM

 roadcase  

 

 

Please check whether all the products you ordered are supplied.  

 

3. Description of the  StarHazer II

TM

 

o

 

The StarHazer II 

TM

  has new DMX control with 5 pin in/out panel mounts that are protected 

by the protruding sidewalls.  The unit now has 3 pin XLR remote with locking connector. The 
improved, higher pressure compressor provides finer haze using less fluid while making haze. 
It is by far a much longer-lasting haze effect than conventional water-based hazers or foggers, 
which is completely safe for people, children, and animals to breathe.  There is no odor with 
toxin-free High Performance Fluid haze.  One tiny half ounce of fluid per hour of constant 
operation testifies to the tiny amount of particles being used to create such long lasting effects 
(3-4 hours), compared to hazers using a quart per half hour or more. 

o

 

California Occupational Safety and Health Association tested this haze fluid to determine that 

"people working for 40 hours a week for 50 years would not suffer any adverse health 
effects".  This is due to: A) the very low amount of fog fluid being used, B) the highest grade 
medicinal mineral oil being used, C) absolutely no heating element to create the irritation 
usually associated with hazing machines. 

 
o

 

Haze from the StarHazer II

TM 

 Haze Machine is completely different from any other hazer on 

the market. It operates without the use of a heating element (heating elements that create a 
heated chemical reaction for haze).  The fire departments have been extremely happy to hear 
that this machine won’t catch on fire if allowed to run empty, because it is made to operate 
without any type of heater or other fire causing generation.   

Summary of Contents for STARHazer II

Page 1: ...STARHazer IITM Operating Instructions P N 100033 100038 120 VAC 230v...

Page 2: ...uct is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great haze effects i...

Page 3: ...ng the StarHazerTM 5 5 1 Selecting the Location 5 2 Electrical Power Requirements 5 3 Hooking things up 5 4 Operating the machine 5 5 Troubleshooting 5 6 Notes on Optional DMX Control 6 Service and Ma...

Page 4: ...to breathe There is no odor with toxin free High Performance Fluid haze One tiny half ounce of fluid per hour of constant operation testifies to the tiny amount of particles being used to create such...

Page 5: ...g installation o Risk of electrical shock Never open the machine without disconnecting power lead first This device is supplied with a grounding conductor To reduce risk of electrical shock connect on...

Page 6: ...causing irreversible damage to the tank and possibly damaging the compressor or hoses 2 Check for proper matching voltage outlet Plug in cord provided 5 4 Operating the machine 1 Allow a 12 open area...

Page 7: ...fluid for clarity If separation is seen discard and fill with fresh fluid 5 5 Troubleshooting 1 If the fuse blows If hazer stops working first check fuse located under the plug Remove the plug With a...

Page 8: ...e and Maintenance Care of your StarHazer IITM will give you years of service Note cleaning your unit is going to pay off in constant good performance 1 When finished wipe machine with a clean cloth an...

Page 9: ...Limited Warranty Five year limited warranty on tank and compressor 90 days on electrical components Remote Control On off cycle timer 25 cord 3 pin XLR in out connectors 0 60 s On 0 4 m Off Added Fea...

Page 10: ...not guarantee replacement rights nor do faults or defects caused by water by generally abnormal environment conditions or Force Majeure 1 Faulty parts will be repaired or replaced manufacturer s choi...

Page 11: ...vice do not forget to remove any liquid from the fluid bottle and place unit in original box Obtain your RMA by calling CITC Payment arrangements for repair must be made before receiving RMA in case u...