background image

Operating the AQUAMAX™ MP using DMX Control 

 

With DMX control, you will be able to adjust both the haze levels and fan speeds on/off, 
from 0 – 100%.  By adjusting the push button switches on the back of the machine near 
the display panel, the user may assign one DMX address to the AQUAMAX™ MP, giving 
you on/off and volume control with this DMX channel. The display will show which 
channel has been selected. Do not select a channel above 511, as there are only 512 
channels and you will require 2 of them. 

 

Step 1).   Attach the DMX cable to the upper “in” female connector located on the back of 
the hazer. DMX control overrides the manual remote. When a DMX cable is connected, a 
small dot will appear on the LED display at the bottom right of the “ones” digit. 
 
Step 2).   The DMX address is configured by pressing the 3 small DMX pushbuttons on 
the control panel, located directly beneath the display. The left button controls 100’s, the 
center button controls 10’s, while the right button controls single digits. Set the DMX 
address from 1 to 511.  

 

When you move the slide control or digital control; 

 

0 – 5%   

 

= Off  

5– 80%    

 

= Volume Control  

80 – 100% 

  

= For Maximum Output  

 
The 2

nd

 channel of DMX control will allow you a full range of control for the speed of the 

on-board haze distribution fans. This 2

nd

 channel will be the next one above the channel 

you have selected for haze output control. For example, if you have the LED readout set 
at 214, then channel 214 will control your haze output and channel 215 will control your 
fan speed. It will also turn off the fans and air after the haze has been shut off for 60 
seconds. This helps distribute all haze evenly and “cleans” the head. 
 
 “Input” and “Output” designations on the DMX plugs are arbitrary (i.e., you can use the 
input plug for output and vice-versa). It is not necessary to attempt converting your DMX 
line’s connector to female/male to match the appropriate socket on the plug. As long as it 
is looped in/out, it will work. 
 
Once your hazer is warm and the green “READY” light on the remote is on, you can 
control the haze output from the control booth. 
 

5.5

 

Rest Period 

 

Continuous operation of the AQUAMAX™ MP can be accomplished when OUTPUT is 
set at the “100%”, or 5 o’clock position.  If for any reason the unit cools down, a short rest 
period for reheating is necessary.  

 

5.8  Troubleshooting 

 

1. 

If the pump does not draw fluid 

into the hazing unit, check electrical power to the 

machine. Be sure the unit is warm and ready to operate.  Then check to see that the 

Summary of Contents for AQUAMAX MP 100059

Page 1: ...Organic Haze Machine Operating Instructions P N 100059 120 VAC w DMX P N 100060 230 VAC w DMX...

Page 2: ...s quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great haze effects if you...

Page 3: ...Operating the AQUAMAX MP 4 5 1 Selecting the Location 5 2Electrical Power Requirements 5 3Hooking things up 5 4Operating the machine with Remote Control 5 5Operating the machine using DMX Control 5 6R...

Page 4: ...R in out P N 600387 1 Bracket for hanging P N 601994 Operating Instructions Booklet 2 Accessories and Parts CITC Organic HazeTM P N 150580 C Clamp w Safety Cable P N 250110 C Clamp w eyebolt hanging h...

Page 5: ...s Never remove the third prong from the plug o Be sure area around hazer is dry before applying electrical power o The AquaMax MP should only be used in a level position o Make sure that your unit is...

Page 6: ...control KNOB 3 Using the yellow TIMER KNOBS button you may adjust the ON and OFF knobs to set the haze cycle times NOTE Do not depress VARY OUTPUT when using timer To prime the pump if your AQUAMAX MP...

Page 7: ...The 2nd channel of DMX control will allow you a full range of control for the speed of the on board haze distribution fans This 2nd channel will be the next one above the channel you have selected fo...

Page 8: ...enance and Storage Care of your AQUAMAX MP will give you years of service Note cleaning your unit is going to pay off in constant good performance 1 Dry all areas on the exterior of the machine once i...

Page 9: ...0VAC 5A Fluid Consumption 50 100 output 4 8 oz 125 250 ml per hour Fluid Type CITC Organic Haze 2 Liter or 5 gallon Warm up time 6 minutes Haze hang time 2 hours DMX 1 channel haze volume on off 1 cha...

Page 10: ...ion is not covered by this warranty Using any fluid other than what is recommended for this machine will void warranty No liability is accepted for injury or for loss damage or expense resulting from...

Page 11: ...eight costs to and from CITC when under the limited warranty services are the responsibility of the customer Customer must place appropriate insurance on return of product However if product is return...

Reviews: