Page 34
To help you troubleshoot the dryer, we list below the most common
reasons for service calls and some answers to the problems.
Before
you call service
, please review the following items:
DRYER WON’T START
1. Is the door completely closed?
2. Are the controls set to the
“on”
position?
3. Did you push the
“start”
control?
4. Has a fuse blown or a circuit breaker tripped?
5. Are the fuses tight?
6. Check for low voltage.
DRYER WON’T HEAT
1. Is the dryer set for
“cooling time”
rather than
“drying
time”
?
2. Are the gas valve in the dryer and the valve on the main gas
line turned on?
3. Check for low or intermittant
gas pressure
.
CLOTHES ARE NOT SATISFACTORILY DRY
1.
Timed cycle
—Did you allow enough heating time before the
cool-down part of the cycle?
2. Is the lint screen blocked?
3. Is the exhaust duct to the outside clean and not blocked?
(A
blocked exhaust will cause slow drying and other
problems.)
GAS DRYER IGNITION
The dryer has a safety device which automatically shuts off the gas
if the burner fails to light in a short time. If this happens, turn the
dryer off. Check and see if the manual gas valve is open.
Wait 5
minutes for the safety device to reset
. Then reset the dryer
controls. If the dryer still fails to heat, call for service.
All panels,
covers and doors must be in place and closed before starting the
dryer
.
VERY IMPORTANT
When calling the factory for service, always refer to the
model number and serial number.
VERY IMPORTANT
When calling the factory for service, always refer to the
model number and serial number.
Service Savers
TROUBLESHOOTING
DRYER WON’T START
DRYER WON’T HEAT
CLOTHES ARE NOT
SATISFACTORILY DRY
GAS DRYER IGNITION
Summary of Contents for L28FD30
Page 1: ...R1 2 07...
Page 10: ...Page 10 110 lb Gas Fired Dryer Models L44CD42G and L44KD42G Illustration...
Page 11: ...Page 11 110 lb Steam Heated Dryer Models L44CD42S and L44KD42S Illustration...
Page 12: ...Page 12 110 lb Electric Dryer Model L44CD42E Illustration...
Page 13: ...Page 13 110 lb Gas Fired Dryer Models L44FD42G and L44RD42G Illustration ENERGY SAVERMODEL...
Page 19: ...Page 19 Gas Loop Piping and Gas Supply Piping System Illustrations...
Page 23: ...Page 23 Steam Piping Installation Illustration...
Page 25: ...Page 25 10 16cm Dryer Installation with Multiple Exhaust Illustration...
Page 31: ...Page 31 Two Timer Models Figures 1 2 and 3 Illustrations...