Page 6
Diagnostic Microprocessor Control (DMP)
General Operation
The Cissell Diagnostic Microprocessor Control (DMP) is designed to manage the drying and cooling cycles
of the gear cabinet. The controller is also programmed from the the factory with five different default pro
grams as described below. The operator has the flexibility to select the time for the drying and cool down
cycles and the drying temperature. The operator may also re-program the default programs. See
paragragh 4.0.
1.0
Dry Time
90 Minutes
120 Minutes
150 Minutes
180 Minutes
20 Minutes
Cool Time
2 Minutes
2 Minutes
2 Minutes
2 Minutes
2 Minutes
Temp. Set Point
110°F (43°C)
110°F (43°C)
110°F (43°C)
110°F (43°C)
110°F (43°C)
Reversing
N/A
N/A
N/A
N/A
N/A
Note: If a modified program is determined to be corrupted, the default program settings will be used.
Default Programs
Programs
1
2
3
4
5
2.0 Features
1.
Drying time: 0-180 minutes
2.
Cooling time: 2-60 minutes
3.
LED display of cycle time, set temperature, and actual temperature
4
Thermistor controlled temperature
5.
Buzzer for end of cycle, audible alarm
6.
Five user programmable programs
7.
Monitors the thermistor for operation
8.
Reversing button is not used in this application
The minimum drying time is 0 minutes, and the minimum cooling time is 2 minutes. The maximum
drying or cooling time is 180 minutes. The drying temperature may be set from 100°F (38°C) to
150°F (66°C). The drying time, cooling time, or temperature may be modified during an operating
cycle.
If necessary to reset the drying and cooling times for the current cycle, press STOP once to stop
the gear cabinet. Press STOP again to cancel the cycle.
DIAGNOSTIC MICROPROCESSOR CONTROL - FEATURES
Summary of Contents for Gear Cabinet
Page 11: ...Page 11 MAIN ASSEMBLY...
Page 16: ...Page 16 WIRING SCHEMATIC AGC65 240V 50 60 3...
Page 17: ...Page 17 WIRING SCHEMATIC AGC64 240V 50 60 1...
Page 18: ...Page 18 WIRING SCHEMATIC AGC45 208V 60 3...
Page 19: ...Page 19 WIRING SCHEMATIC AGC44 208V 60 1...
Page 20: ...Page 20 LADDER DIAGRAM AGC65 240V 50 60 3...
Page 21: ...Page 21 LADDER DIAGRAM AGC64 240V 50 60 1...
Page 22: ...Page 22 LADDER DIAGRAM AGC45 208 60 3...
Page 23: ...Page 23 LADDER DIAGRAM AGC44 208 60 1...
Page 24: ...Page 24...