10
3
The machine must be placed on a flat, solid surface (metal base, concrete or solid
ground). It is
recommended that the machine be anchored
(bolts M10) on the
provided places (A) in the base, especially in case of a plint (see Dimensions 2).
The machine must be placed entirely level. For easy maintenance it is recommen-
ded to keep a minimal distance of 600 mm between the wall and the back of the
machine.
If several machines are placed next to each another, there should be a minimal
distance of 30 mm between each machine.
To prevent damage during transportation, the machine has been
equipped with two red transport brackets (D) to eliminate every
possible movement of the tub.
After the machine has been placed level, take off the service panel
and remove these transport brackets.
Important
The machine must never be activated
before removing
these transport brackets.
Removing the transport brackets
The machine is delivered with hoses with 3/4" connections. These hoses fit the
water inlet valves of the machine and the main water inlet taps. To ensure the
optimal functioning of the water inlet valves, the water pressure on the inlet
should be between 0,5 and 10 kg/cm² (7 and 145 psi). If the pressure is too low,
the cycle time will increase considerably.
In case of boiler fed machines, a minimum of hot water of 90°C should
be available: HW55: 46l. HW64: 55 l. HW75: 65 l. HW94: 80l.
HW131: 100l. HW164: 120l.
Water connection
Water drain
The machine is equipped with a drain valve with 6/4" outer diameter (50 mm). This
drain valve should be connected to the drain by means of the drain elbow which
is delivered with the machine.
The diameter of the main drain should be adapted to the water flow and the
number of machines. It should be sufficient to handle at least 80L/min. per
machine.
It is necessary to connect the main drain at least on one side to an open air-
brake to allow ventilation.
p
p
Installation and connection
Ground
Important
The bolt pattern for the fixation of the HW 55 machine is foreseen in the back
panel of the cabinet. Put this panel on the floor and indicate the holes (see page
7).
Summary of Contents for CSHW35-HW55-164