PROBLEM
PROBLEM
PROBLEM
PROBLEM
PROBLEM
(10)
Inadequate steam flow
(11)
Blower motor will start,
steam starts but won’t
stop
(12)
Blower Motor won’t
stop
CA
CA
CA
CA
CAUSE
USE
USE
USE
USE
10A
Steam valve linkage not
properly adjusted
10B
Steam time set too
short
11
Defective steam timer
12A
Defective Air timer
12B
Defective blower relay
REMEDY
REMEDY
REMEDY
REMEDY
REMEDY
Adjust linkage according to
adjustment instructions.
Tighten all set screws and lock
nuts.
Set steam timer for longer time.
Tighten knob set screw if
necessary.
Check timer operation. See if
timer switch operates properly.
If operation is not correct,
replace the timer.
Check timer operation. See if
timer switch operates properly.
If operation is not correct,
replace the timer.
Check to see if relay operates
properly on rated current. If
contacts are stuck or welded
shut, or relay does not operate
properly, replace it.
Aire F
Aire F
Aire F
Aire F
Aire Form
orm
orm
orm
orm AF1 Suggested Spare P
AF1 Suggested Spare P
AF1 Suggested Spare P
AF1 Suggested Spare P
AF1 Suggested Spare Parts
arts
arts
arts
arts
P
P
P
P
Part
art
art
art
art
No.
No.
No.
No.
No.
Description
Description
Description
Description
Description
F218
Clamp Leaf Spring
F267
Pivot Pin w/”E” Rings
F63
Covered Spring Asm.
F11
Set No. 11 Sleevers
F433
Sponge for Front Paddle
AF165
Sponge for Rear Paddle
F904
Foam Rubber Pads, Vent Clamp
F357
Felt Air Seal
F287
Bearing Adjust Screw
F18
Steam Spreader Asm.
F739H
Solenoid
F738H
Solenoid
V30
Pack Ring
TU13224
RBM Relay, 115V
TU13225
RBM Relay, 230V
FG453
Timer
AF185
Toggle Switch
AF102
Air Filter
SKD147
Repair Kit for SG147 Gun
SG148
Teflon Hose Assy. for SG147
K451
Repair Kit for FV110 Valve