(Optional) Console cable or USB cable
11
Compliance documentation
(78-100866-01)
4
(Optional) Power cord retainer
12
Two 19-inch mounting brackets
5
Icon legend label (47-103380-01)
13
Cable guide
6
Four Number-12 Phillips pan-head screws
(48-0523-01)
7
Tools and Equipment
Obtain these necessary tools:
•
A Number-2 Phillips screwdriver to rack-mount the switch
Installation Guidelines
When determining where to install the switch, verify that these guidelines are met:
•
Clearance to the switch front and rear panel meets these conditions:
◦
Front-panel LEDs can be easily read.
◦
Access to ports is sufficient for unrestricted cabling.
◦
AC power cord can reach from the AC power outlet to the connector on the switch rear panel.
•
Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting
fixtures. Make sure that the cabling is safely away from other devices that might damage the cables.
•
Airflow around the switch and through the vents is unrestricted.
•
Temperature around the unit does not exceed 113°F (45°C). If the switch is installed in a closed or
multirack assembly, the temperature around it might be greater than normal room temperature.
•
Humidity around the switch does not exceed 90 percent.
•
Altitude at the installation site is not greater than 10,000 feet.
•
For 10/100/1000 fixed ports, the cable length from a switch to a connected device cannot exceed 328
feet (100 meters).
•
Cooling mechanisms, such as fans and blowers in the switch, can draw dust and other particles causing
contaminant buildup inside the chassis, which can result in system malfunction. You must install this
equipment in an environment as free from dust and foreign conductive material (such as metal flakes
from construction activities) as is possible.
Cisco Catalyst 2960-L Series 24-Port and 48-Port Switch Hardware Installation Guide
17
Switch Installation
Tools and Equipment