A-2
Cisco UCS C460 Server Installation and Service Guide
OL-22326-01
Appendix A Server Specifications
Environmental Specifications
Environmental Specifications
Table A-2
lists the environmental specifications for the server.
Power Specifications
Table A-3
lists the specifications for each power supply.
You can get more specific power information for your exact server configuration by using the Cisco UCS
Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Table A-2
Environmental Specifications
Description
Specification
Temperature, operating
10ºC to 35ºC (50ºF to 95ºF)
Temperature, non-operating
-40ºC to 70ºC (-40ºF to 158ºF)
Humidity, non-operating
95%, non-condensing at temperatures of
25ºC (77ºF) to 30ºC (86ºF)
Altitude
-30m to 1500m (-100ft to 5000ft)
Table A-3
Power Supply Specifications
Description
Specification
AC input voltage
200 to 240 VAC nominal (Range: 180 to 264 VAC)
Low AC input voltage
(limited to 800W system configurations)
100 to 120 VAC nominal (Range: 90 to 132 VAC)
AC input frequency
50 to 60 Hz nominal (Range: 47 to 63 Hz)
Maximum AC-input current
10A
Maximum output power for each power
supply
1200 W (up to two power supplies can be installed)
Power supply output voltage
Main power: 12 VDC
Standby power: 12 VDC