S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
23
Cisco UCS B440 High Performance Blade Server Installation and Service Note
OL-22475-01
Memory and Performance
Installing Memory
Check the server's service profile setting in UCS Manager before adding memory to make sure that the
new memory will be recognized. To install a DIMM into the blade server, follow these steps:
Step 1
Open both DIMM connector latches, refer to callout 1 in
Figure 12
.
Figure 12
Installing DIMMs in the Blade Server
Step 2
Press the DIMM into its slot evenly on both ends until it clicks into place, refer to callout 2 in
Figure 12
.
The DIMM connector latches will snap into place.
Note
DIMMs are keyed and will only insert into their slot if the notch at the bottom of the DIMM is oriented
correctly. Attempting to force an incorrectly oriented DIMM will damage the slot.
Step 3
Press the DIMM connector latches inward slightly to seat them fully. Refer to callout 3 in
Figure 12
.
Memory and Performance
This section describes the type of memory that the blade server requires, and its effect on performance.
The following topics are covered:
•
Supported DIMMs
•
Memory Arrangement
•
Memory Performance
•
Related Documentation
196877
1
3
1
3
2
2