1-11
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
OL-8787-05
Warning
To avoid potential electrical shock, operate this unit only when the cover is in place.
Warning
To avoid potential electrical shock, use only a grounded (three wire) electrical outlet.
Warning
Keep objects that might damage this unit and liquids that might spill clear from this unit. Liquids and
foreign objects that come into contact with voltage points could create the risk of fire or electrical
shock.
Caution
Do not overload the power supply branch circuit providing power to the rack. The total rack load should
not exceed 80 percent of the branch circuit rating.
Caution
Keep power cord and connection cables clear of obstructions that might cause damage.
Caution
Do not attempt to service the unit yourself. The first course of action is to contact Technical Support.
Note
Unplug this unit from the electrical outlet and refer servicing to a qualified service center if any of the
following conditions occur:
–
The power cord is damaged or frayed.
–
The unit has been dropped or the case has been damaged.
–
The unit has been exposed to any liquids.
–
The unit does not operate normally when all operating instructions have been followed.
–
The unit exhibits a distinct change in performance, indicating a need for service.
Tools, Equipment and Personnel Required
•
An ESD wrist strap
•
A #2 Phillips screwdriver
•
Pen (felt-tip) to mark the mounting holes
•
Three people to complete the installation (highly recommended). The SFS 7012 switch chassis
weighs up to 100 pounds fully loaded.
Check the Installation Site
The SFS 7012
switch is designed to be installed in an existing server cabinet (not a telco cabinet), where
it can be mounted in a standard equipment rack. Mounting brackets are integrated with the switch.