6-5
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
OL-10853-01
Chapter 6 Hardware Diagnostic Tests
About Diagnostic Tests
Figure 6-1
Power Supply Numbers on the Cisco SFS 7000P and SFS 7000D Server Switches
Enter the
show diagnostic fan
command.
SFS-7000P#
show diagnostic fan
======================================================================
Diagnostic Tests For Fan
======================================================================
module-type : fan
module-number : 2
test : self-test
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Fan Self Test Completed, Final report : Passed=1, Failed=0,
Total=1
Step 2
Enter the
diag fan
id
command.
SFS-7000P#
config
SFS-7000P(config)#
diag fan 1
SFS-7000P(config-diag-fan-1)# test self-test
SFS-7000P(config-diag-fan-1)# start
SFS-7000P(config-diag-fan-1)# exit
SFS-7000P(config)# exit
SFS-7000P# show diag fan
======================================================================
Diagnostic Tests For Fan
======================================================================
module-type : fan
module-number : 1
test : self-test
iterations : 1
action : start
result : in-progress
percentage-completed : 70
result-string : Self Test, Current report : In progress...
SFS-7000P#
Step 3
Display the progress of the test by entering the
show diag fan
command.
SFS-7000P(config-diag-fan-1)#
exit
SFS-7000P(config)#
exit
181046
Power Supply
1
Power Supply
2