background image

Contents

iv

Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide

78-10853-01

Administrative Features

1-5

Real-Time Clock

1-5

Latency

1-5

Nonvolatile Memory

1-5

Diagnostics

1-5

C H A P T E R

 

2

Preparation for Installation

2-1

Safety

2-1

Site Requirements

2-1

Temperature

2-2

Humidity

2-2

Altitude

2-2

Dust and Particles

2-3

Corrosion

2-3

Electromagnetic and Radio Frequency Interference

2-3

Shock and Vibration

2-4

Power Source Interruptions

2-4

Preventing Electrostatic Discharge Damage

2-4

Air Flow

2-5

Power Requirements

2-5

Site Preparation Checklist

2-6

C H A P T E R

 

3

Installing the Switches

3-1

Safety

3-2

Pre-installation Instructions

3-2

Rack-Mounting the Switches

3-3

Requirements

3-3

Rack-Mounting the Switch

3-3

Installing the Switch with One Person

3-4

Installing the Switch with Two People

3-6

Configuring Basic Connectivity

3-7

Obtaining an IP Address

3-7

Obtaining an IP Address from the DHCP Server for Ethernet Management

3-7

Obtaining a Static IP Address for Ethernet Management

3-8

Connecting the 10/100 Ethernet Management Port

3-10

Powering Up the Chassis

3-10

Connecting Network Devices

3-11

Connecting InfiniBand Devices

3-12

Summary of Contents for SFS 7000D

Page 1: ...0 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 526 4100 Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide November 2006 Text Part Number OL 10853 01 ...

Page 2: ...or the other of the television or radio Move the equipment farther away from the television or radio Plug the equipment into an outlet that is on a different circuit from the television or radio That is make certain the equipment and the television or radio are on circuits controlled by different circuit breakers or fuses Modifications to this product not authorized by Cisco Systems Inc could void...

Page 3: ...Products xvi Product Alerts and Field Notices xvi Obtaining Technical Assistance xvii Cisco Technical Support Documentation Website xvii Submitting a Service Request xviii Definitions of Service Request Severity xviii Obtaining Additional Publications and Information xviii C H A P T E R 1 Product Overview 1 1 Introduction to Switches 1 1 Switch Connectors 1 2 Switch Components 1 2 LEDs 1 3 Power S...

Page 4: ...ectrostatic Discharge Damage 2 4 Air Flow 2 5 Power Requirements 2 5 Site Preparation Checklist 2 6 C H A P T E R 3 Installing the Switches 3 1 Safety 3 2 Pre installation Instructions 3 2 Rack Mounting the Switches 3 3 Requirements 3 3 Rack Mounting the Switch 3 3 Installing the Switch with One Person 3 4 Installing the Switch with Two People 3 6 Configuring Basic Connectivity 3 7 Obtaining an IP...

Page 5: ...InfiniBand Port LEDs 5 3 Power Supply LEDs 5 3 Managing the System with Element Manager 5 4 Using the Summary Tab 5 5 Using the Power Supplies Tab 5 5 Using the Fans Tab 5 5 Using the Sensors Tab 5 6 Displaying System Information 5 6 Displaying Power Supply Information 5 6 Displaying Fan Information 5 7 Displaying Sensor Information 5 7 C H A P T E R 6 Hardware Diagnostic Tests 6 1 About Diagnosti...

Page 6: ...finiBand Server Switches Hardware Installation Guide 78 10853 01 A P P E N D I X A Specifications and Compliance Certifications A 1 Chassis and Management Interface A 1 Electrical Specifications A 2 A P P E N D I X B Acronyms and Abbreviations 3 ...

Page 7: ... overview of the Cisco SFS 7000P and SFS 7000D Server Switches features Chapter 2 Preparation for Installation Provides an overview about safety and site preparation requirements Chapter 3 Installing the Switches Describes how to install the switches in a rack Chapter 4 Installing Field Replaceable Units Describes how to install and remove field replaceable units FRUs on the switches Chapter 5 Man...

Page 8: ...upply values are in italics Elements in square brackets are optional x y z Alternative keywords are grouped in braces and separated by vertical bars x y z Optional alternative keywords are grouped in brackets and separated by vertical bars string A nonquoted set of characters Do not use quotation marks around the string or the string will include the quotation marks screen font Terminal sessions a...

Page 9: ...isia vammoja Ennen kuin käsittelet laitteistoa huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla SÄILYTÄ NÄMÄ OHJEET Attention IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce sy...

Page 10: ...ocê está em uma situação que poderá ser causadora de lesões corporais Antes de iniciar a utilização de qualquer equipamento tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize se com as práticas habituais de prevenção de acidentes Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que ...

Page 11: ...xi Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 Preface Conventions ...

Page 12: ...Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo GUARDE ESTAS INSTRUÇÕES Advarsel VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare Du befinder dig i en situation med risiko for legemesbeskadigelse Før du begynder arbejde på udstyr skal du være opmærksom på de involverede risici de...

Page 13: ...xiii Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 Preface Conventions ...

Page 14: ...ch Hardware Installation Guide Cisco SFS 7000 Series Product Family Chassis Manager User Guide Cisco SFS 7000 Series Product Family Element Manager User Guide Cisco SFS 7000 Series Product Family Command Reference Regulatory Compliance and Safety Information for the Cisco SFS 7000P SFS 7000D SFS 7008P and SFS 3012R Server Switches InfiniBand SDR DDR and QDR Technical Overview Obtaining Documentati...

Page 15: ...place docstore Ordering Documentation You must be a registered Cisco com user to access Cisco Marketplace Registered users may order Cisco documentation at the Product Documentation Store at this URL http www cisco com go marketplace docstore If you do not have a user ID or password you can register at this URL http tools cisco com RPF register register do Documentation Feedback You can provide fe...

Page 16: ... encourage you to use Pretty Good Privacy PGP or a compatible product for example GnuPG to encrypt any sensitive information that you send to Cisco PSIRT can work with information that has been encrypted with PGP versions 2 x through 9 x Never use a revoked encryption key or an expired encryption key The correct public key to use in your correspondence with PSIRT is the one linked in the Contact S...

Page 17: ...ster do Note Use the Cisco Product Identification Tool to locate your product serial number before submitting a request for service online or by phone You can access this tool from the Cisco Technical Support Documentation website by clicking the Tools Resources link clicking the All Tools A Z tab and then choosing Cisco Product Identification Tool from the alphabetical list This tool offers three...

Page 18: ...initions of Service Request Severity To ensure that all service requests are reported in a standard format Cisco has established severity definitions Severity 1 S1 An existing network is down or there is a critical impact to your business operations You and Cisco will commit all necessary resources around the clock to resolve the situation Severity 2 S2 Operation of an existing network is severely...

Page 19: ...ocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in designing developing and operating public and private internets and intranets You can access the Internet Protocol Journal at this URL http www cisco com ipj Networking products offered by Cisco Systems as well as customer support services can be obtained at this URL http www cisco com en US pr...

Page 20: ...xx Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 Preface Obtaining Additional Publications and Information ...

Page 21: ...000D Server Switches are described in the following sections Introduction to Switches page 1 1 Switch Connectors page 1 2 Switch Components page 1 2 System Features page 1 3 Administrative Features page 1 5 Introduction to Switches The Cisco SFS 7000P and SFS 7000D Server Switches offer features that are described in the following sections Figure 1 1 shows an illustration of the Cisco SFS 7000P Se...

Page 22: ...he Cisco SFS 7000D Server Switch uses the following connectors Twenty four dual speed 20 Gbps 4x copper InfiniBand ports that are capable of operating in either 20 Gbps DDR or 10 Gbps SDR mode for server and interswitch connectivity One 10 100 Ethernet RJ 45 management Ethernet port for out of band management One RJ 45 console port used to configure and monitor the Cisco SFS 7000D Server Switch No...

Page 23: ...an be successfully completed without removing the device from a rack or disconnecting any cables Auto ranging 90 to 264 VAC 47 to 63 Hz Redundant hot swappable cooling See the Installing a Power Supply Module section on page 4 2 for more information System Features This section describes the system features of the Cisco SFS 7000P and SFS 7000D Server Switches and includes the following topics Infi...

Page 24: ...single InfiniBand port fails none of the other ports have interrupted service Fabric High availability is supported at the fabric level as well For redundancy InfiniBand HCAs can be dual connected to a redundant pair of switches When an InfiniBand fabric includes more than one Cisco SFS 7000P Server Switch or Cisco SFS 7000D Server Switch and the subnet manager fails on the Cisco SFS 7000P Server ...

Page 25: ... port to port latency of less than 200ns The Cisco SFS 7000D Server Switch has port to port latency of less than 140ns Nonvolatile Memory The nonvolatile memory supports the following items Three stored system images not including recovery image One week of log files at normal verbosity and one day of log files at maximum verbosity Diagnostics The following tests are used to determine operational ...

Page 26: ...1 6 Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 Chapter 1 Product Overview Administrative Features ...

Page 27: ... equipment Statement 1030 Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Site Requirements These sections describe some of the basic site requirements that you should be aware of as you prepare to install your Cisco SFS 7000P and SFS 7000...

Page 28: ...rticularly important at high altitudes Make sure that all slots and openings on the system remain unobstructed especially the fan vent on the chassis Clean the installation site at regular intervals to avoid buildup of dust and debris which can cause a system to overheat If the system has been exposed to abnormally cold temperatures allow a two hour warm up period to bring it up to normal operatin...

Page 29: ... from a system can also interfere with cordless and low power telephones Conversely RFI from high power telephones can cause spurious characters to appear on the system monitor RFI is defined as any EMI with a frequency above 10 kHz This type of interference can travel from the system to other devices through the power cable and power source or through the air like transmitted radio waves The FCC ...

Page 30: ...ients or spikes can erase data from memory or even cause components to fail To protect against these types of problems power cables should be grounded properly Also place the system on a dedicated power circuit rather than sharing a circuit with other heavy electrical equipment In general do not allow the system to share a circuit with any of the following Copy machines Air conditioners Vacuum cle...

Page 31: ... the airflow through the chassis Consider heat dissipation of all equipment when determining the air conditioning requirements as specified in the hardware installation guide When evaluating airflow requirements consider that hot air generated by equipment at the bottom of the rack can be drawn into the intake ports of the equipment above Power Requirements Follow these requirements when preparing...

Page 32: ...e a successful switch installation Table 2 1 Site Planning Checklist Task No Planning Activity Verified By Time Date 1 Space evaluation Space and layout Floor covering Impact and vibration Lighting Maintenance access 2 Environmental evaluation Ambient temperature Humidity Altitude Atmospheric contamination Airflow 3 Power evaluation Receptacle proximity to the equipment Dedicated separate circuits...

Page 33: ...ng wrist straps to avoid ESD damage to the card Do not directly touch the backplane with your hand or any metal tool or you could shock yourself Statement 94 Warning Read the installation instructions before connecting the system to the power source Statement 1004 Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use...

Page 34: ... open or both Statement 1043 Warning This product requires short circuit overcurrent protection to be provided as part of the building installation Install only in accordance with national and local wiring regulations Statement 1045 Warning Class 1M laser radiation when open Do not view directly with optical instruments Statement 1053 Warning Use of controls adjustments or performing procedures ot...

Page 35: ...ottom to the top with the heaviest component at the bottom of the rack If the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack Statement 1006 This section describes how to install the Cisco SFS 7000P and SFS 7000D Server Switches in an equipment rack Requirements In addition to the accessories provided with the switch you need the ...

Page 36: ...o install the switch with one person follow these steps Step 1 Separate one set of the rack brackets See Figure 3 1 Each side is assembled to its counterpart but should be separated before you attach them to the switch when you use this installation method Figure 3 1 Assembled Rack Brackets Step 2 Attach the bracket that has the screw holes to the side of the switch with the flange facing away fro...

Page 37: ...f the rack with the flange facing away from the rack The flange should go around the outside of the rack post as shown in Figure 3 3 Figure 3 3 Holding Bracket Inside of Rack Note If you are rack mounting the switch backward the bracket should be installed to the front of the rack b Secure the bracket with the screws through the back of the rack as shown in Figure 3 4 c Repeat on the other side of...

Page 38: ... Into the Rack Step 8 Maintain at least six inches between the cooling vents and any obstructions Step 9 Secure the switch with your screws through the front of the rack as shown in Figure 3 6 Figure 3 6 Secure Switch with Screws through the Front of the Rack Installing the Switch with Two People The following installation method requires two people to mount the switch into the rack One person hol...

Page 39: ...the front rails to the front of the rack with screws that fit your rack See Figure 3 6 Configuring Basic Connectivity The following sections appear in this section Obtaining an IP Address page 3 7 Connecting the 10 100 Ethernet Management Port page 3 10 Powering Up the Chassis page 3 10 Obtaining an IP Address Obtaining an IP Address from the DHCP Server for Ethernet Management This section descri...

Page 40: ... can configure a static IP address and connect to a serial console port only if a DHCP server is not available To configure a static IP address you must connect the serial console port to a PC serial for access to the server switch Before you configure the switch ensure that the unit is connected properly This section describes how to attach a serial console cable to a PC The serial console port l...

Page 41: ... serial console port See Figure 3 7 and Figure 3 8 Connect the other end to the DB 9 RJ 45 female adapter or DB 25 RJ 45 adapter at the PC serial port After you connect the serial console port you may configure a static IP address for the Ethernet management interface by following these steps Step 1 Wait for the login prompt Login Step 2 Enter the username and password The default username is supe...

Page 42: ... Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Statement 1034 When you power up the chassis use only the power cable provided with your InfiniBand system To power up the chassis follow these steps Step 1 Remove the power cords from the shipping package Two power cords are available UL rated 10 amps and 125 VAC or greater Step 2 Insp...

Page 43: ...ers up it performs a POST See the LEDs section on page 5 1 Step 6 Log in and assign a network address after you see the login prompt The default login is super and the default password is super For additional management information see the Cisco SFS 7000 Series Product Family Command Reference Connecting Network Devices This section describes how to connect the InfiniBand switches to other network...

Page 44: ... InfiniBand cables can be used to connect any two InfiniBand devices whether a switch or a host Figure 3 11 and Figure 3 12 show InfiniBand ports on the Cisco SFS 7000P and SFS 7000D Server Switches For more information about InfiniBand cables see the InfiniBand SDR DDR and QDR Technology Overview Note Copper passive DDR cables are limited to 8 meters in length If you want to use a longer SDR cabl...

Page 45: ...ector and Figure 3 14 shows an InfiniBand cable with a pull connector Figure 3 13 InfiniBand Cable with Pinch Connector Figure 3 14 InfiniBand Cable with Pull Connector Note If your host does not provide an ample amount of space around an InfiniBand port double check that your InfiniBand cable connector engages fully Move your connector back and forth to be sure that both sides of the connector ha...

Page 46: ...t with your other hand and gently move the connector back and forth and away from the port See Figure 3 16 Figure 3 16 Removing a Pull Connector Connecting Ethernet Management Devices To connect the Ethernet management port to external devices such as switches routers and hubs use an Ethernet cable For the location of the Ethernet management port see Figure 3 11 and Figure 3 12 Managing the System...

Page 47: ...l connection Telnet over IP or SSH over IP Chassis Manager GUI A web based graphical user interface Element Manager GUI A graphical interface installed on a workstation accessible over IP See the Cisco SFS 7000 Series Product Family Command Reference Cisco SFS 7000 Series Product Family Chassis Manager User Guide and the Cisco SFS 7000 Series Product Family Element Manager User Guide for more info...

Page 48: ...3 16 Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 Chapter 3 Installing the Switches Managing the System ...

Page 49: ...les Each power supply module contains a power supply and a fan unit Both power modules are located at the front of the switch When facing the front of the switch the power supply modules are located in the left and right slots of the switch Failed Power Supply Modules The status of a power supply module can be checked using the CLI the Chassis Manager or the Element Manager The available informati...

Page 50: ... Caution Never place your hand inside an empty module bay or anywhere inside the Cisco SFS 7000P and SFS 7000D Server Switches Caution Unused module bays always should have a switch filler panel over the bay to ensure proper safety ventilation and cooling To insert a power supply module follow these steps Step 1 Ground yourself appropriately Step 2 Remove the filler panel from the power supply bay...

Page 51: ...r Supply from the Switch Step 4 Insert the new power supply module into the open slot until it is fully seated You might need to push the unit with your thumbs to ensure that it is seated completely in the bay Step 5 Secure fasteners with a number 1 Phillips or a slotted screwdriver Step 6 Check the LEDs to verify the status of the module See Figure 4 3 for the location of the LEDs For more inform...

Page 52: ...le bay or anywhere inside the Cisco SFS 7000P and SFS 7000D Server Switches Step 3 Locate the power supply module that you want to remove If you have two power supply modules installed you can remove one of them without removing power from the switch Step 4 Unscrew the fasteners that hold the power supply module in place See Figure 4 4 Figure 4 4 Removing the Screws from the Power Supply of the Sw...

Page 53: ...e bi color chassis status LED The rear of the chassis has one green and one yellow chassis status LED that convey the identical information as the single chassis status LED in the front of the chassis See Table 5 1 for information about interpreting the chassis status LED and see Figure 5 1 through Figure 5 4 for the locations of the chassis status LEDs Table 5 1 Interpreting the Chassis Status LE...

Page 54: ...rver Switch Showing Chassis Status LED Figure 5 3 Rear View of Cisco SFS 7000P Server Switch Showing Chassis Status LEDs Figure 5 4 Rear View of Cisco SFS 7000D Server Switch Showing Chassis Status LEDs 180716 Bi color chassis status LED Power Supply 1 Cisco Systems 180718 Bi color chassis status LED Power Supply 1 Status Cisco Systems SFS 7000D 180717 Yellow chassis status LED Green chassis statu...

Page 55: ...Server Switch Figure 5 6 InfiniBand Port LEDs Location for the Cisco SFS 7000D Server Switch Table 5 2 describes the InfiniBand Port LED operation Power Supply LEDs Each power supply module contains a power supply and a fan The power supply module LEDs are located on the bottom left corner of each power supply module For the location of the LEDs see Figure 5 7 For LED descriptions see Table 5 3 Th...

Page 56: ...co SFS 7000 Series Product Family Element Manager User Guide To view the Health Status window perform the following steps Step 1 Launch the Element Manager Step 2 Select Health Status The Health Status window opens See Figure 5 8 Figure 5 8 Health Status Window Table 5 3 Power Supply Module LEDs Color Indication Green off No DC input Green solid AC connected DC output OK Yellow off No failure on t...

Page 57: ...ning properly A red check indicates that the power supply AC is disconnected Fans A green check indicates that at least one fan is present and functions properly A red check indicates a fan failure Sensors A green check indicates that the system temperature is at an acceptable level A red check indicates a high temperature warning Using the Power Supplies Tab Use the Power Supplies tab to view the...

Page 58: ...nsor functions properly The temperature fields show temperatures in Celsius The Current Temp field shows the current internal temperature The Alarm Temp field shows the temperature at which the system goes above its internal temperature limit The Shutdown Temp field shows the temperature at which the system powercycles For operating and non operating temperatures see Table A 1 on page A 1 Displayi...

Page 59: ...fan oper status speed 1 up 73 2 up 73 3 up 73 4 up 73 Fan Seeprom product pca pca fru fan serial number serial number number number 1 2 3 4 Displaying Sensor Information To display information about the sensors enter the show sensor command SFS 7000P show sensor Sensor Information sensor oper status oper code temperature c alarm temp c shutdown temp c 1 1 up normal 29 65 73 The temperature fields ...

Page 60: ...5 8 Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 Chapter 5 Managing the Switch Displaying System Information ...

Page 61: ...th the Element Manager GUI see the Cisco SFS 7000 Series Product Family Element Manager User Guide A POST is run automatically on various components at power on The following sections refer to running and displaying tests with the CLI For complete diagnostic command information see the Cisco SFS 7000 Series Product Family Command Reference LED Tests LED tests allow you to set a particular LED to b...

Page 62: ...sco SFS 7000D Server Switch you would see a similar display To perform a diagnostic self test on a card follow these steps Step 1 Enter the diag card number command SFS 7000P enable SFS 7000P config SFS 7000P config diag card 11 SFS 7000P config diag card 11 test self test SFS 7000P config diag card 11 start Step 2 Exit the test to view the progress of the test The test takes approximately 5 to 8 ...

Page 63: ... chassis The power supply and fan unit contained in the power supply module The base card To perform a chassis standard test follow these steps Step 1 Start the test by entering the diag chassis test standard command and the start command SFS 7000P enable SFS 7000P config SFS 7000P config diag chassis test standard SFS 7000P config diag chassis start SFS 7000P config diag chassis Step 2 Display th...

Page 64: ... _FRU_POWER_CONTROLLER_CONFIG_ERR card 12 passed none card 13 passed none card 15 passed none card 16 passed none card 17 passed none fan 1 passed none Running Fan Self Test The procedures in this section describe the fan module tests and provide sample text from performing a fan test Note The sample text in the steps below shows command output for the Cisco SFS 7000P Server Switch For the Cisco S...

Page 65: ... Self Test Completed Final report Passed 1 Failed 0 Total 1 Step 2 Enter the diag fan id command SFS 7000P config SFS 7000P config diag fan 1 SFS 7000P config diag fan 1 test self test SFS 7000P config diag fan 1 start SFS 7000P config diag fan 1 exit SFS 7000P config exit SFS 7000P show diag fan Diagnostic Tests For Fan module type fan module number 1 test self test iterations 1 action start resu...

Page 66: ... error command SFS 7000P show diag fru error Fru Error fru slot fru error card 1 none card 2 none card 7 none card 8 none card 9 none card 10 none card 11 none card 12 none card 13 none card 14 none card 15 none card 17 none fan 1 none fan 2 none Step 5 Reboot the chassis when the self test is complete SFS 7000P reload System configuration is modified Save yes default no filename y Proceed with re...

Page 67: ...7000P show power supply Power supply Information ps type admin status oper status utilization voltage 1 AC up up n a 48 2 AC up up 15 47 Step 2 Specify the type of test self test is chosen by default by entering the diag power supply id command SFS 7000P enable SFS 7000P config SFS 7000P config diag power supply 2 SFS 7000P config diag power supply 2 test self test Step 3 Start the test SFS 7000P ...

Page 68: ...on fatal errors that can are recovered informational logging such as firmware updates and hardware errors follow these steps Step 1 Enter the more syslog hwif_log command to see the contents of the hardware log file SFS 7000P enable SFS 7000P more syslog hwif_log Thu Mar 4 10 57 49 2004 POST SEEPROM PASSED Thu Mar 4 10 57 49 2004 POST FPGA PASSED Thu Mar 4 10 57 49 2004 POST SUMMIT PASSED Thu Mar ...

Page 69: ...ailed 1 0 0 0 fan 1 passed 0 0 0 0 fan 2 passed 0 0 0 0 power supply 1 passed 0 0 0 0 Step 2 Display FRU errors on your switch by entering the show diagnostic fru error command SFS 7000P show diagnostic fru error Fru Error fru slot fru error card 1 _FRU_POWER_CONTROLLER_CONFIG_ERR fan 1 none fan 2 none power supply 1 none Table 6 1 lists the hardware errors that are logged for the power supply Tab...

Page 70: ...6 10 Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 Chapter 6 Hardware Diagnostic Tests Displaying Hardware Errors ...

Page 71: ...operating temperature 40 to 70 C 40 to 158 F Operating temperature gradient 20 C 68 F max per 60 min Operating altitude 0 to 3 048 m 0 to 10 000 ft Nonoperating altitude 0 to 12 192 m 0 to 40 000 ft Operating humidity 8 to 80 non condensing Nonoperating humidity 5 to 90 RH at 65 C 149 F for 24 hours non condensing Operating humidity gradient 10 maximum per 60 min Operating shock 5 G max 11 ms half...

Page 72: ...r Switches Table A 2 Cisco SFS 7000P and SFS 7000D Server Switches Electrical Specifications Category Specification AC input Auto ranging 90 to 264 VAC 47 to 63 Hz Power consumption Power with external powered1 devices is 125 Watts Power without external powered devices is 65 Watts Cisco SFS 7000P Server Switch Power without external powered devices is 80 Watts Cisco SFS 7000D Server Switch 1 Exte...

Page 73: ... Expansion API Application Program Interface C Celsius CLI command line interface DDR double data rate EMI electromagnetic interference ESD electrostatic discharge FCC Federal Communications Commission FRU field replaceable unit GUI graphical user interface GUID globally unique identifier HCA Host Channel Adapter kHz kilohertz OEM original equipment manufacturer POST power on self test RFI radio f...

Page 74: ...R E V I E W D R A F T C I S CO CO N F I D E N T I A L B 4 Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 Appendix B Acronyms and Abbreviations ...

Page 75: ...up 3 10 Chassis Self Test 6 3 chassis status LED bi color 5 1 single 5 1 configure connectivity 3 7 connect InfiniBand devices 3 12 management devices 3 14 network devices 3 11 connectivity configuring 3 7 connector types 3 11 console port 1 2 conventions document viii corrosion 2 3 D data bits 3 9 DDR 1 2 1 3 degradation performance 1 2 dehumidifier 2 2 diagnostics 1 3 1 5 diagnostic tests 6 1 di...

Page 76: ... 4 2 emulation software 3 9 environmental factors 2 1 ESD 2 4 grounding strap 2 4 preventative ankle strap 3 2 preventative wrist strap 3 2 Ethernet cable 3 14 exhaust fans 2 3 F fabric switches high performance 1 1 low latency 1 1 fan information display 5 7 Fan Self Test 6 4 Fans tab 5 5 FCC regulations 2 3 filler panel 4 4 flange 3 4 3 7 FRU power supply module 4 1 G general specifications A 1 ...

Page 77: ...son 3 4 with two people 3 6 interface chassis A 1 management A 1 interswitch connectivity 1 2 L latency 1 5 latency port to port 1 5 LED list 1 3 test 6 1 test power supply 6 7 lightning 2 3 logical link 5 3 logical link activity 5 3 login default 3 11 low pressure 2 2 M management interface A 1 port 3 14 specifications A 1 management devices connect 3 14 management Ethernet port 1 2 metal connect...

Page 78: ... requirements 2 5 power source interruptions 2 4 Power Supplies tab 5 5 power supply bay 1 3 errors 6 9 failed 4 1 features 1 3 FRU 4 1 hot swappable 1 3 4 1 information display 5 6 install 4 2 LED 5 3 LED test 6 7 module 1 3 module removal 4 4 redundant 1 3 Self Test 6 7 test 6 6 unit 4 1 without 4 4 power supply module 1 3 power up chassis 3 10 pull connector 3 13 3 14 R rack mount switch 3 3 ra...

Page 79: ... specifications electrical A 2 general A 1 management A 1 spikes 2 4 status fan 1 3 overall system 1 3 power 1 3 show link 1 3 stop bits 3 9 subnet manager 1 4 Summary tab 5 5 switch components 1 2 LED 1 3 system information display 5 6 T temperature conditions 2 2 extreme 2 2 fluctuations 2 2 transients 2 4 U undervoltage 2 4 unused module bay 4 2 V ventilation 2 2 2 5 vibration 2 4 voltage varia...

Page 80: ...Index IN 10 Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide OL 10853 01 ...

Reviews: