41 to 95°F (5 to 35°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above
sea level.
Temperature, operating
–40 to 149°F (–40 to 65°C)
Temperature, Non-operating
(when the server is stored or transported)
10 to 90%
Humidity (RH), operating
5 to 93%
Humidity (RH), non-operating
(when the server is stored or transported)
0 to 10,000 feet
Altitude, operating
0 to 40,000 feet
Altitude, non-operating
(when the server is stored or transported)
5.5
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
40
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
Power Specifications
Do not mix power supply types or wattages. Both power supplies must be identical.
Note
The power specifications for the supported power supply options are listed in the following sections.
770 W AC Power Supply
This section lists the specifications for each 770 W AC power supply.
Table 6: 770 W AC Specifications
Specification
Description
Nominal range: 100–120 VAC, 200–240 VAC
(Range: 90–132 VAC, 180–264 VAC)
AC Input Voltage
Cisco Secure Network Server 3600 Series Appliance Hardware Installation Guide
28
Server Specifications
Power Specifications