55
5. Appendix A: DMS100 Switch Datafill
Example
The datafills on DMS100 needs to be configured in order to work with the
Unified ICM. The following example depicts the datafill on a DMS100
Switch:
A.1.
TABLE: MPC
MPCNO MPCIOC IOCCCT EQ DLDFILE
3 0 28 1X89BB MPC403AC **** CompuCALL Link to Cisco Peripheral
Gateway (PG)
5 2 12 1X89BB MPC403AC **** CompuCALL Back-up Link to Cisco PG
Notes
:
1.
MPCIOC is actual DMS IOC Number (i.e. 0 or 1 or 2 or 3, etc)
2.
IOCCCT is in reference to actual IOC Card Number of 1X89 card on
IOC Shelf (i.e. card 0 = ioccct 0, card 1 = iocct 4, …..card 8 = ioccct
32)
3.
1X89 must be 1X89BA or BB if running 56K and must match actual
card installed)
4.
DLDFILE can be MPC403AC or MPC003AC (Nortel recommends
MPC403AC)
A.2.
TABLE: MPCLINK
LINKKEY LINKALM PRTCLDAT
3 3 Y X2580 0 0 (CLKSRCE EXTERNAL) (L2WINDOW 7) (L3WINDOW 7)
(NODETYPE DTE) (ELECSPEC V35) (L3DATA P128) (N2 10)
(SVCS2WAY 1) $ (SVCDNA 19092502500) $
5 3 Y X2580 0 0 (CLKSRCE EXTERNAL) (L2WINDOW 7) (L3WINDOW 7)
(NODETYPE DTE) (ELECSPEC V35) (L3DATA P128) (N2 10)
(SVCS2WAY 1) $ (SVCDNA 29092502500) $
Notes
:
1.
MPCNO must match MPCNO assigned in table MPC
2.
LINKNO must be set to 3 when configuration is running 56K
3.
Even though the LINKNO is 3 for 56K the cable connected to the back
of the IOC Shelf must be physically connected to Link 1. Link 1 is the
V35 Link.