In the event that only one power supply is operating in an active system and a
second power supply is inserted, the system fan will slow down to
50% of Max
speed
for 12 seconds. It can take up to 10 seconds for the second power supply
to become active. Please do not remove the first power supply during this
time-frame, in order to avoid system shutdown.
Note
The following figure shows the switch features on the port side of the chassis.
8 100/400-Gigabit
QSFP-DD ports
Ports 29-34 support 4x10
and 4x25G as port profile
converted downlinks
3
Beacon (BCN), Status
(STS), and Environment
(ENV) LEDs
1
28 40/100-Gigabit
QSFP28 ports
Ports 25-28 support
4x10G and 4x25G
breakout as native
downlinks
2
To determine which transceivers, adapters, and cables are support this switch, see the
Modules Compatibility Information
document.
The following figure shows the switch features on the power supply side of the chassis.
Management port
(1—RJ-45 copper port)
4
Power supply modules (1
or 2) (AC power supplies
shown) with slots
numbered 1 (left) and 2
(right)
1
Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide
3
Overview
Overview