Description
Direction
Name
Pin #
Digital IO Common Return
Return
Return
5
Digital Input and Output Specifications are described in
and
.
Table 3 is considered “dry contact”, and Table 4 is considered “wet contact”.
Table 3: Digital Input Specification
Unit
Maximum
Minimum
Specification
Volts
60
2.2
Input Voltage High
Volts
1.2
-
Input Voltage Low
uA
0.68mA
Note1
-
Input Current
Note1
: Current is flowing out of the terminal although it is an input, i.e. sourcing. The current is flowing in
the terminal for the output, i.e. sinking.
Table 4: Digital Output Specification
Notes
Unit
Maximum
Minimum
Specification
No external voltage
applied.
Volts
2.5
Output Voltage High
No external voltage
applied.
Volts
0.4
-
Output Voltage Low
Ohms
3.3K – 1%
3.3K – 1%
Internal Pull-up
Resistance
Volts
3
-
Internal Pull-up Voltage
External resistance
required to limit current
to 200mA.
Volts
60
3.3
External Pull-up Voltage
mA
200
Sink Current
Common features of the Digital I/O are:
• Withstands up to 60V applied at the terminal.
• Reverse voltage protected and causes no damage to the equipment.
• Digital input and output can coexist on different channel.
• LED Indicator: provision-able, On: Active, Off: Non-active.
• Electrical isolation: 2000 VDC.
• 4kV Surge protected (IEC 61000-4-5).
IR1101 Industrial Integrated Services Router Hardware Installation Guide
16
Product Overview
Digital I/O Connector