No Downstream Signal Lock
68-4004214-01 Rev D
127
Check and Correct
1
On initial installation, or after a reset, allow the cable modem gateway 5 to 8
minutes to locate and lock on to the downstream channel.
2
Using the Web browser on the PC attached to the cable modem gateway, access
the WebWizard by entering the following IP address:
http://192.168.100.1
. The
Web browser accesses the WebWizard and the Default page opens.
3
Select the
Signal
page and verify that the cable modem gateway locks to the
downstream channel of the CMTS.
4
Check the power level and the Signal-to-Noise ratio to verify if it is outside of the
operating range.
5
Is the ratio outside of the operating range?
If
yes
, correct the downstream channel to the cable modem gateway.
If
no
, go to step 6.
6
Check the status of the CMTS.
7
Check the status of the CMTS signal on the node attached to the cable modem
gateway.