Cisco Catalyst PON Series Switches Hardware Installation Guide

First Published:

2020-11-08

Last Modified:

2021-09-26

Americas Headquarters

Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 527-0883

Summary of Contents for Catalyst PON Series

Page 1: ...ardware Installation Guide First Published 2020 11 08 Last Modified 2021 09 26 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Page 2: ... Series OLT Overview 2 Cisco Catalyst PON Series OLT Models 2 Front Panel 3 Rear Panel 4 Ports 4 Power Supply 5 LEDs 6 Cisco Catalyst PON Series ONT Overview 7 Cisco Catalyst PON Series ONT Models 8 Front Panel 8 Rear Panel 10 Side Panel 10 Top Panel 11 Ports 13 LEDs 13 Lock Slot 15 Cisco Catalyst PON Manager Overview 15 Installation 17 C H A P T E R 2 Cisco Catalyst PON Series Switches Hardware I...

Page 3: ... 30 Installing an ONT 30 Placing the ONT on a Table or Shelf 31 Installing the ONT on a Wall 31 Attaching the Rack Mounting Bracket and Mounting an ONT on a Rack 33 Connecting to an AC Power Source 34 Setting Up an ONT 35 Installing Cisco Catalyst PON Manager 35 Setting Up Cisco Catalyst PON Manager 40 Starting PON Manager Server 40 Creating a New User in PON Manager Client 41 Remove and Replace F...

Page 4: ...odule 57 Interface Indicator 57 Finding a Cisco Catalyst PON OLT Serial Number 57 Cisco Catalyst PON Series ONT Troubleshooting 58 Finding the Cisco Catalyst PON ONT Serial Number 58 Technical Specifications 59 A P P E N D I X A Cisco Catalyst PON Series OLT Technical Specifications 59 Physical Specifications 59 Environmental Specifications 59 Power Requirements 60 Cisco Catalyst PON Series ONT Te...

Page 5: ... Module Connectors 63 Cables and Adapters 64 Transceiver Module Network Cables 64 Cable Pinouts 65 Console Port Adapter Pinouts 66 Cisco Catalyst PON Series Switches Hardware Installation Guide v Contents ...

Page 6: ...Cisco Catalyst PON Series Switches Hardware Installation Guide vi Contents ...

Page 7: ...Document Conventions on page vii Related Documentation on page ix Obtaining Documentation and Submitting a Service Request on page ix Document Conventions This document uses the following conventions Description Convention Both the symbol and Ctrl represent the Control Ctrl key on a keyboard For example the key combination D or Ctrl D means that you hold down the Control key while you press the D ...

Page 8: ...rks around the string or the string will include the quotation marks string Nonprinting characters such as passwords are in angle brackets Default responses to system prompts are in square brackets An exclamation point or a pound sign at the beginning of a line of code indicates a comment line Reader Alert Conventions This document may use the following conventions for reader alerts Means reader t...

Page 9: ... Command Reference Cisco Catalyst GPON ONT Configuration Guide Cisco Catalyst GPON Regulatory Compliance and Safety Information Obtaining Documentation and Submitting a Service Request For information on obtaining documentation submitting a service request and gathering additional information see the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco techn...

Page 10: ...Cisco Catalyst PON Series Switches Hardware Installation Guide x Preface Obtaining Documentation and Submitting a Service Request ...

Page 11: ...he main characteristics of PON is the use of passive optical splitters in the fiber distribution network enabling a single feeding fiber from the service provider s central office to serve multiple homes and small businesses The network path between the terminals is known as Optical Device Network ODN which comprises passive optical components such as optical fibers and passive optical splitters T...

Page 12: ...Catalyst PON Series OLT manages the network traffic that is in the form of video data and voice signals in a PON network and sends them downstream to the Cisco Catalyst PON Series ONTs on the network The Cisco Catalyst PON Series OLT also receives the signals from the Cisco Catalyst PON Series ONTs located at an end user s premises and sends them to their destination over the internet A Cisco Cata...

Page 13: ...n describes the front panel components of Cisco Catalyst PON Series OLT Figure 2 Front Panel of CGP OLT 8T System LEDs 7 PON ports 1 Auxiliary port 8 1 G combo ports 2 Reserve alarm port 9 10 G SFP ports 3 Port LEDs 10 Reserve alarm port 4 Grounding connector 11 Console port 5 Power modules 12 Fan module 6 Figure 3 Front Panel of CGP OLT 16T 10 G SFP port 5 System LEDs 1 Auxiliary port 6 Console p...

Page 14: ...yst PON Series OLT to a host such as a Windows workstation or a terminal server through the auxiliary port The auxiliary out of band management port is a virtual routing and forwarding VRF interface and uses an RJ 45 crossover cable 1 G Combo Ports A combo port is a combination of an SFP interface and an RJ 45 port When the SFP interface is active the adjacent RJ 45 port is disabled The 1 G ports ...

Page 15: ...he Cisco Catalyst PON Series OLT chassis has redundant power supply slots that operate with one or two power supply modules The chassis supports field replaceable AC input and DC input power supply modules Hybrid power supply plugs are not supported Note AC Power Supply The following table lists the power supply ratings Output Power Watts Input Voltage VAC 100 220 100 110 Cisco Catalyst PON Series...

Page 16: ...ormal power from power supply Green solid PWR1 and PWR2 No power from power supply OFF OLT is running normally Green blinking RUN OLT is not running or OLT is running abnormally OFF or Green solid Auxiliary port is not connected OFF AUX Auxiliary port is connected but not transmitting data Green solid Auxiliary port is connected and is transmitting data Green blinking Power supply is normal Green ...

Page 17: ...atalyst PON Series ONT connects to the PON network on one side and accesses the end user s devices in FTTH or FTTO or FTTC service delivery architecture on the other side The Cisco Catalyst PON Series ONT communicates between the Cisco Catalyst PON Series OLT and the end user devices In the upstream direction a Cisco Catalyst PON Series ONT is connected to the optical splitter through the PON port...

Page 18: ...ort and 1xUSB Type A port CGP ONT 4P Cisco Catalyst PON ONT with 1xPON port 4x1 G 10 100 1000 PoE port 1xUSB Type A port and 2xFXS port CGP ONT 4PV Cisco Catalyst PON ONT with 1xPON port 4x1 G 10 100 1000 PoE port 1xUSB Type A port 2xFXS port and 1xCATV port CGP ONT 4PVC Cisco Catalyst PON ONT with 1xPON port 4x1 G 10 100 1000 port 2xFXS port 1xUSB Type A port 1xCATV port and supports 802 11ac wir...

Page 19: ... FXS LED2 4 PON port 10 1 G LED 5 1 Not available on all ONT models 2 Not available on all ONT models Figure 7 Front panel of CGP ONT 4TVCW 1 G ports 4 Power button 1 USB Type A port 5 DC power connector 2 Cisco Catalyst PON Series Switches Hardware Installation Guide 9 Introduction to Passive Optical Network Front Panel ...

Page 20: ... ONT 1P Grounding connector 3 Lock slot 1 AC power connector 2 Figure 9 Rear Panel of CGP ONT 4PVC Lock slot 3 AC power connector 1 Grounding connector 2 Side Panel The section describes the side panel components of CGP ONT 4TVCW Cisco Catalyst PON Series Switches Hardware Installation Guide 10 Introduction to Passive Optical Network Rear Panel ...

Page 21: ...CW Reset button 3 Light button 1 WiFi button 2 Top Panel This section describes the top panel components of CGP ONT 4TVCW Cisco Catalyst PON Series Switches Hardware Installation Guide 11 Introduction to Passive Optical Network Top Panel ...

Page 22: ...anel of CGP ONT 4TVCW CATV LED 5 Power LED 1 2 4 GHz LED 6 PON LED 2 5 GHz LED 7 1 G LED 3 FXS LED 4 Cisco Catalyst PON Series Switches Hardware Installation Guide 12 Introduction to Passive Optical Network Top Panel ...

Page 23: ... type A console port is provided for log and configuration file management CATV Port The CATV port uses a coaxial cable LEDs You can use the LEDs to monitor the activity and performance of Cisco Catalyst PON Series ONT Table 5 LEDs on CGP ONT 1P CGP ONT 4P CGP ONT 4PV and CGP ONT 4PVC Indication Color LED Normal power from power supply Green solid PWR No power from power supply OFF ONT is active a...

Page 24: ...ble is connected but input power is not within normal range OFF Table 6 LEDs on CGP ONT 4TVCW Indication Color LED Normal power from power supply Green solid PWR No power from power supply OFF ONT is active and registered successfully Green solid PON ONT is either inactive or being registered Green flashing Loss in optical signal power Red flashing PON module is not ready OFF Link is up but is not...

Page 25: ... on the rear panel You can install an optional cable lock such as the type that is used to secure a laptop computer to secure the Cisco Catalyst PON Series ONT Cisco Catalyst PON Manager Overview Cisco Catalyst PON Manager is a software platform with highly customized and scalable network management Based on the configurations Cisco Catalyst PON Manager can automatically discover various data devi...

Page 26: ...Cisco Catalyst PON Series Switches Hardware Installation Guide 16 Introduction to Passive Optical Network Cisco Catalyst PON Manager Overview ...

Page 27: ... connected to power and ground and can cause serious burns or weld the metal object to the terminals Statement 43 Warning Do not stack the chassis on any other equipment If the chassis falls it can cause severe bodily injury and equipment damage Statement 48 Warning To comply with FCC radio frequency RF exposure limits antennas should be located at a minimum of 7 87 inches 20 cm or more from the b...

Page 28: ...servicing the unit in the rack Statement 1006 Warning Class 1 laser product Statement 1008 Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Warning The plug socket combination must be accessible at all times because it serves as the main di...

Page 29: ... are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device Statement 1071 Warning Voltages that prese...

Page 30: ...d Accessories Table 7 Cisco Catalyst PON Series OLT and Accessories Quantity Description Component 1 CGP OLT 8T Model CGP OLT 16T 2 Mounting brackets Accessories 4 Rubber mounting feet 1 Power cord 1 Grounding wire 6 Mounting brackets to chassis screws 4 Mounting brackets to cabinet screws 10 4 Mounting brackets to cabinet screws 12 1 Pointer card Cisco Catalyst PON Series ONT and Accessories Tabl...

Page 31: ...T 4PVC 2 Mounting brackets Accessories 4 Rubber mounting feet 1 RJ 45 to RJ 45 crossover cable 1 Power cord 8 Mounting brackets to chassis screws 4 Mounting brackets to cabinet screws 10 4 Mounting brackets to cabinet screws 12 1 Pointer card Table 10 CGP ONT 4TVCW and Accessories Quantity Description Component 1 CGP ONT 4TVCW Model 1 RJ 45 to RJ 45 crossover cable Accessories 1 Power adapter 1 Po...

Page 32: ...he switch does not exceed 90 percent Altitude at the installation site is not greater than 5 000 feet 1524 meters For 10 100 1000 fixed ports the cable length from the Cisco Catalyst PON Series ONT to a connected device cannot exceed 328 feet 100 meters Cooling mechanisms such as fans and blowers in the device can draw dust and other particles causing contaminant buildup inside the device which mi...

Page 33: ...ovided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack Statement 1006 Warning Before you begin You should have the 19 inch rack mounting bracket that is included with the shipping box Procedure Step 1 Use the Phillips head screwdriver and attach the 19 inch rack mounting bracket to an OLT using the mounting bracket screws Follow the same steps to ...

Page 34: ...nts for the switch For information about installing removing cabling and troubleshooting SFP modules see the module documentation that is shipped along with your device Installing an SFP or SFP Module Before you begin When installing SFP or SFP modules observe these guidelines Do not remove the dust plugs from the modules or the rubber caps from the fiber optic cable until you are ready to connect...

Page 35: ...orts of the SFP or SFP module to keep the optical interfaces clean Step 4 If the module has a bale clasp latch pull the bale out and down to eject it from the module If the latch is obstructed and you cannot use your finger use a small flat blade screwdriver or any other long and narrow instrument to open the latch Step 5 Grasp the SFP or SFP module and carefully remove it from the module slot Ste...

Page 36: ...ave a separate ground Note Required Tools and Equipment To connect the system ground you need the following tools and materials Grounding lug When using the double hole lug connector provided with the system the ground wire must be 6 AWG only Otherwise a supported closed loop ring connector must be used for 8 AWG to 14 AWG wire Grounding screws One M4 x 8 mm metric pan head screws Supplied as part...

Page 37: ... 15 Connecting the System Ground for CGP OLT 16T Grounding wire with grounding lug 2 1xM4 screw 1 Step 2 Prepare the other end of the grounding wire with a ring lug and secure it to the rack with a screw Cisco Catalyst PON Series Switches Hardware Installation Guide 27 Installation Connecting the System Ground ...

Page 38: ...ust not connect the power supply directly to the earth ground Use one power cord for each power supply to connect the power supply to its power source Connecting to an AC Power Source Take care when connecting units to the supply circuit so that wiring is not overloaded Statement 1018 Warning Before you begin Prior to connecting the power supply to a power source ensure that the chassis is properl...

Page 39: ...ng procedures ensure that power is removed from the DC circuit Statement 1003 Warning Hazardous voltage or energy may be present on DC power terminals Always replace cover when terminals are not in service Be sure that the uninsulated conductors are not accessible when cover is in place Statement 1075 Warning Before you begin Prior to connecting the power supply to a power source ensure that the c...

Page 40: ...ot is completed Setting Up the OLT Procedure Step 1 Connect the RJ 45 connector end of the cable to the OLT console port Step 2 Connect the DB 9 adapter end to the serial port of a connected device such as a PC Step 3 Reconfigure and reboot the connected device if required Step 4 On the connected device run the terminal emulation program such as Windows HyperTerminal Step 5 Set the following conne...

Page 41: ...the ONT with its front panel facing down or to the side to prevent airflow restriction and to provide easier access to the cables Caution Procedure Step 1 Determine where you want to mount the ONT Verify that the surface is smooth flat dry and sturdy Step 2 Drill two pilot holes into the surface of the wall 153 20 mm apart Step 3 Insert a screw into each hole leaving a gap between the surface and ...

Page 42: ...rew 3 CGP ONT 1P 1 Mounting bracket 2 Step 5 Place the bottom of the ONT over the screws on the wall and slide the ONT down until the screws fit snugly into the slots Cisco Catalyst PON Series Switches Hardware Installation Guide 32 Installation Installing the ONT on a Wall ...

Page 43: ...rning Before you begin Make sure that you have the mounting brackets that are included with the shipping box Procedure Step 1 Use the Phillips head screwdriver and attach a rack mounting bracket to an ONT using the mounting bracket screws Follow the same steps to attach the second bracket to the other side Figure 19 Attaching Rack Mounting Brackets to a CGP ONT 4PVC Front mounting position 3 8xMou...

Page 44: ... power cable into the power connector on the ONT Figure 20 Connecting an AC Power Cable to the CGP ONT 4PVC Step 2 Plug the other end of the power cable into a power source Step 3 Verify that the power supply is receiving power by checking whether the PWR LED is green If the LED does not turn on check the power connections on the power supply and the power source Note Cisco Catalyst PON Series Swi...

Page 45: ... Packets Sent 4 Received 4 Lost 0 0 loss Approximate round trip times in milli seconds Minimum 2ms Maximum 3ms Average 2ms Step 3 To log in to the device using an internet browser on your PC enter the IP address 192 168 1 1 in the address bar of your internet browser and press Enter Step 4 Enter the following default credentials and press Enter username cisco password cisco Installing Cisco Cataly...

Page 46: ...on The License Agreement page is displayed Step 4 Click Yes to accept the end user license agreement and continue with the installation Click Print to print the agreement Cisco Catalyst PON Series Switches Hardware Installation Guide 36 Installation Installing Cisco Catalyst PON Manager ...

Page 47: ...ll page is displayed Step 5 Click Browse to change the folder location Click Next to continue with the installation Cisco Catalyst PON Series Switches Hardware Installation Guide 37 Installation Installing Cisco Catalyst PON Manager ...

Page 48: ... Step 6 Click Next to start the installation If the installation is successful the installation complete page is displayed Cisco Catalyst PON Series Switches Hardware Installation Guide 38 Installation Installing Cisco Catalyst PON Manager ...

Page 49: ...inish to complete the installation The server and client shortcut icons are created on the desktop Cisco Catalyst PON Series Switches Hardware Installation Guide 39 Installation Installing Cisco Catalyst PON Manager ...

Page 50: ... Step 1 Double click on the PON Manager Server icon if installed on the desktop or click the Windows Start button and navigate to Cisco Catalyst PON Manager PON Manager Server The PON Manager Server settings window is displayed Step 2 Continue clicking Next till the PON Manager Server home page is displayed Cisco Catalyst PON Series Switches Hardware Installation Guide 40 Installation Setting Up C...

Page 51: ... 1 Double click on the PON Manager Client icon if installed on the desktop or click the Windows Start button and navigate to Cisco Catalyst PON Manager PON Manager Client The login page is displayed Cisco Catalyst PON Series Switches Hardware Installation Guide 41 Installation Creating a New User in PON Manager Client ...

Page 52: ...efault password as cisco Step 3 Click Login A pop up message is displayed asking you to change the user name and password Cisco Catalyst PON Series Switches Hardware Installation Guide 42 Installation Creating a New User in PON Manager Client ...

Page 53: ...Step 4 Click OK to continue The Change Default User dialog box is displayed Cisco Catalyst PON Series Switches Hardware Installation Guide 43 Installation Creating a New User in PON Manager Client ...

Page 54: ...rd The allowed character range is from 8 to 64 Step 7 In the Confirm Password field reenter the new password Step 8 To save the changes click Apply A confirmation message is displayed Step 9 Click OK The login page is displayed Cisco Catalyst PON Series Switches Hardware Installation Guide 44 Installation Creating a New User in PON Manager Client ...

Page 55: ...e if they are not aligned with the module A fan module that is only partially connected to the device can disrupt the system operation The device supports hot swapping of the fan module You can remove and replace the module without interrupting normal device operation Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Warning Removing...

Page 56: ...fan module 1 Step 2 Grasp the fan module handle and slide the fan module half way out of the bay Gently move it from side to side if necessary to unseat it from the OLT Step 3 Place your other hand underneath to support the bottom of the fan module and then remove the fan module completely Figure 22 Removing the Fan Module from the CGP OLT 8T Cisco Catalyst PON Series Switches Hardware Installatio...

Page 57: ...he type of the Cisco Catalyst PON OLT Front panel of CGP OLT 8T Rear panel of CGP OLT 16T Installation Guidelines The device must be installed in a cabinet or rack that is secured to the data center The power supply module must be removed from its shipping container along with packaging if any The following additional tools and equipment are required Nut driver attachment for number 1 Phillips hea...

Page 58: ...ready inserted into the device Ensure that the power source is off As an added precaution place the appropriate safety flag and lockout devices at the source power circuit breaker or place a piece of adhesive tape over the circuit breaker handle to prevent accidental power restoration while you are working on the circuit Caution Before performing any of the following procedures ensure that power i...

Page 59: ...pply unplug the power cables that are attached to the power supply and the power source For the DC input power supply remove the power cables from the power supply and the power source Step 2 Remove the power cables from the OLT as follows For the AC input power supply unplug the power cable that is attached to the power connector to the power supply module For the DC input power supply loosen and...

Page 60: ...he power supply module 2 Figure 24 Removing the AC Power Cable from CGP OLT 16T Power cable 3 Captive installation screw on the power supply module 1 Power supply module handle on the power supply module 2 Cisco Catalyst PON Series Switches Hardware Installation Guide 50 Remove and Replace Field Replaceable Units Removing a Power Supply Module from an OLT ...

Page 61: ...ule Step 4 Grasp the power supply module handle and slide the power supply module half out of the bay Gently move it from side to side if necessary to unseat it from the OLT Step 5 Place your other hand underneath to support the bottom of the power supply module and then remove the module completely Figure 25 Removing the Power Supply Module from CGP OLT 8T Cisco Catalyst PON Series Switches Hardw...

Page 62: ...insert the power supply module into the OLT follow these steps Before you begin If you are installing a spare power supply module see Removing a Power Supply Blank Cover If you are installing a replacement power supply module see Removing a Power Supply Module from an OLT Verify that the power supply is not connected to any power sources Procedure Step 1 Hold the handle on the power supply module ...

Page 63: ...crews on the power supply module to the power supply bay On the rear of CGP OLT 16T use the Phillips head screwdriver and tighten the two captive installation screws on the power supply module to the power supply bay What to do next You can proceed with either of the following actions Connect an AC power source see Connecting to an AC Power Source Connect a DC power source see Connecting to a DC P...

Page 64: ...Cisco Catalyst PON Series Switches Hardware Installation Guide 54 Remove and Replace Field Replaceable Units Inserting the Power Supply Module in an OLT ...

Page 65: ...s on cable connectors Rule out any bad patch panel connections or media convertors between the source and the destination If possible bypass the patch panel or eliminate faulty media convertors fiber optic to copper Test the cable in another port or interface if possible to identify if the fault is with the cable Ethernet and Fiber Optic Cables Make sure that you have the correct cable for the con...

Page 66: ...in the OLT meets the power requirements of your connected devices Verify the cable type Noncompliant cabling or powered devices can cause a PoE port fault Use only standard or compliant cabling to connect Cisco devices You must remove any cable or device that causes a PoE fault Caution Cisco Catalyst PON Series OLT Troubleshooting The following sections describe how to troubleshoot issues relating...

Page 67: ...n Module Power Supply Module The PWR1 and PWR2 LEDs indicate whether the power supply module is faulty For details about the LED indicators of the pluggable power supply module see Table 2 System LEDs on page 6 If the power supply is faulty check the following Check if the pluggable power supply module is turned on Check that the power cable is properly connected Check if the input power matches t...

Page 68: ... Cisco Catalyst PON ONT Serial Number If you contact Cisco Technical Assistance you must know the Cisco Catalyst PON ONT serial number Figure 28 Serial Number Location Cisco Catalyst PON Series Switches Hardware Installation Guide 58 Troubleshoot Cisco Catalyst PON Series ONT Troubleshooting ...

Page 69: ...cations CGP OLT 8T Physical Dimensions 9 92 lbs 4 5 kg Weight 1 73 x 17 3 x 10 82 in 4 4 x 44 0 x 27 5 cm Dimensions H x D x W CGP OLT 16T Physical Dimensions 16 75 lbs 7 6 kg Weight 1 73 x 17 3 x 14 96 in 4 4 x 44 0 x 38 0 cm Dimensions H x D x W Environmental Specifications Environmental Ranges 23 F to 104 F 5 C to 40 C Operating temperature 3 13º to 158ºF 25º to 70ºC up to 15 000 ft 4500 m Stor...

Page 70: ...ollowing sections provide information about the Cisco Catalyst PON Series ONT Physical Specifications CGP ONT 1P Physical Dimensions 0 8 lbs 0 36 kg Weight 1 6 x 6 6 x 6 9 in 4 0 x 16 8 x 17 5 cm Dimensions H x D x W CGP ONT 4P CGP ONT 4PV and CGP ONT 4PVC Physical Dimensions 2 75 lbs 1 25 kg Weight 1 73 x 9 44 x 5 70 in 4 4 x 24 0 x 14 5 cm Dimensions H x D x W CGP ONT 4TVCW Physical Dimensions 2...

Page 71: ...5 noncondensing Storage relative humidity Up to 15 000 ft 4500 m Storage altitude 4 Minimum ambient temperature for cold start is 32 F 0 C Power Requirements Power Requirements 110 to 220 VAC 1 1 A AC input voltage 36W CGP ONT 1P 72 W CGP ONT 4P CGP ONT 4PV and CGP ONT 4PVC 18W CGP ONT 4TVCW Power rating Cisco Catalyst PON Series Switches Hardware Installation Guide 61 Technical Specifications Env...

Page 72: ...Cisco Catalyst PON Series Switches Hardware Installation Guide 62 Technical Specifications Power Requirements ...

Page 73: ...onnector Specifications The following sections provide information about the various connectors 10 100 1000 Ports Including PoE All 10 100 1000 ports use standard RJ 45 connectors and Ethernet pinouts Figure 29 10 100 1000 Port Pinouts SFP Module Connectors Figure 30 Duplex LC Cable Connector Cisco Catalyst PON Series Switches Hardware Installation Guide 63 ...

Page 74: ... see Cisco SFP and SFP Transceiver Module Installation Notes Each port must match the wavelength specifications on the other end of the cable and the cable must not exceed the stipulated length Copper 1000BASE T SFP module transceivers use standard four twisted pair Category 5 cable of lengths up to 328 feet 100 meters Cisco Catalyst PON Series Switches Hardware Installation Guide 64 Connector and...

Page 75: ...ic Identifying a Crossover Cable To identify a crossover cable compare the two modular ends of the cable Hold the cable ends side by side with the tab at the back The wire connected to the pin on the outside of the left plug should be a different color from the wire that is connected to the pin on the inside of the right plug Cisco Catalyst PON Series Switches Hardware Installation Guide 65 Connec...

Page 76: ...e Port Signaling with a DB 9 Adapter Console Device RJ 45 to DB 9 Terminal Adapter Switch Console Port DTE Signal DB 9 Pin Signal CTS 8 RTS DSR 6 DTR RxD 2 TxD GND 5 GND GND 5 GND TxD 3 RxD DTR 4 DSR RTS 7 CTS Table 12 Console Port Signaling with a DB 25 Adapter Console Device RJ 45 to DB 25 Terminal Adapter Switch Console Port DTE Signal DB 25 Pin Signal CTS 5 RTS DSR 6 DTR RxD 3 TxD GND 7 GND Ci...

Page 77: ...nal Adapter Switch Console Port DTE Signal DB 25 Pin Signal GND 7 GND TxD 2 RxD DTR 20 DSR RTS 4 CTS Cisco Catalyst PON Series Switches Hardware Installation Guide 67 Connector and Cable Specifications Connector and Cable Specifications ...

Page 78: ...Cisco Catalyst PON Series Switches Hardware Installation Guide 68 Connector and Cable Specifications Connector and Cable Specifications ...

Page 79: ...he separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product The Cisco implementation of TCP header compressio...

Page 80: ......