2-14
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
OL-19593-01
Chapter 2 Switch Installation
Installing the Switch
StackPower Partitioning Examples
Figure 2-15
and
Figure 2-16
show StackPower stacks of Catalyst 3750-X switches with failover
conditions. In
Figure 2-15
, the StackPower cable 2 is faulty. Therefore, this stack does not provide
redundancy.
Figure 2-15
Example of a StackPower Stack with a Failover Condition
In
Figure 2-16
, StackPower port B on the center switch has failed and this stack partitions into two
stacks. The top two switches share power, and the bottom switch is now a separate stack.
Figure 2-16
Example of a Partitioned StackPower Stack with a Failover Condition
Installing the Switch
•
Rack-Mounting, page 2-14
•
Table- or Shelf-Mounting, page 2-20
•
After Installing the Switch, page 2-21
The illustrations shown in this section show the Catalyst 3750-X-48 PoE switch as an example. You can
install the Catalyst 3750-X and 3560-X switches following the same procedures.