1-9
Catalyst 2360 Switch Hardware Installation Guide
OL-22150-02
Chapter 1 Product Overview
Rear Panel
Figure 1-6
USB Mini-Type B Port
You can use the command-line interface (CLI)
to configure an inactivity timeout that reactivates the
RJ-45 console if the USB console has been activated and no input activity has occurred on the USB
console for a specified time period.
After the USB console deactivates due to inactivity, you cannot use the CLI to reactivate it. Disconnect
and reconnect the USB cable to reactivate the USB console. For information on using the CLI to
configure the USB console interface, see the switch software guide.
Power-Supply Modules
The Catalyst 2360 switch is powered by two 135 W power-supply modules.
The Catalyst 2360 power-supply module is an autoranging unit that supports input voltages
from 100–240 VAC.
The AC-power-supply module uses an 18-AWG power cord for connection to an AC power outlet.
The power-supply modules have one status LED (
For information about replacing a power-supply module and for module specifications, see
“Power Supply and Fan Module Installation,”
and
Appendix A, “Technical Specifications.”
Fan Module
The switch has a hot-swappable 12-V fan module in the rear panel. The air circulation system consists
of the fan module and the power supply modules. You can change the airflow direction by changing the
orientation of the fan module.
In
, the blue arrows show cool air flow, and the red arrows show warm air flow.
253163
Table 1-9
Power-Supply Module LED
Power-Supply Module LED
Green
No AC input power or DC output failure
Off
AC input power present and DC output OK