Procedure
Step 1
Remove the rack-mount brackets from the accessory kit and position them beside the router chassis.
The figure below shows how to attach the brackets on the Cisco ASR 907 Router for a 19-inch EIA rack and
300 mm ETSI Cabinet.
Figure 1: Attaching Mounting Brackets for a 19-inch EIA Rack and 300 mm ETSI Cabinet
Step 2
Position one of the brackets against the chassis side, and align the screw holes.
Step 3
Secure the bracket to the chassis with the screws removed when performing Step 1. The recommended
maximum torque is 28 in.-lb (3.16 N-m).
The A907-FAN-E fan tray with filter (A907-FAN-F) cannot be mounted using the mounting screws that are
supported for fan tray. This is not an issue with the FAN tray filter blank panel (A907-FAN-F-B). We
recommend that you use the short screws provided in the following rack mount kits to avoid interference of
the air filter during rack mounting and while replacing the fan tray with the fan tray filter (A907-FAN-E):
• 19" rack mount kit (A907-RCKMT-19IN)
• ETSI rack mount kit (A907-RCKMT-ETSI)
What to do next
Repeat Step 2 and Step 3 for the other bracket.
Installing the Router Chassis in the Rack
The procedures in this section apply to both horizontal and vertical mounting of the router in a rack.
Installing the Cisco ASR 907 Router
2
Installing the Cisco ASR 907 Router
Installing the Router Chassis in the Rack