four ports of IEEE C37.94 interfaces
Figure 25: C37.94 Interface Module
Figure 26: C37.94 Interface Module Front Panel
For more information about installing the module, see the
Interface Module Installation
section .
Blank Deflector (A900-IMA-BLNK-DEF)
The A900-IMA-BLNK-DEF is a special type of blank filler plate that can be used in empty interface module
slots. In addition to just acting as a filler for the empty slots in the router, this blank deflects additional air
towards the interface modules in the slot below it, thereby enhancing the cooling for the interface module.
The A900-IMA-BLNK-DEF module should not be used in slot 0 in the Cisco ASR 902 Router.
Caution
For slot 0, always use the filler blank (A900-IMA-BLANK) when a blank filler needs to be used.
For more information on operating temperature, see
Maximum Operating Ambient Temperature Support for
.
Maximum Operating Ambient Temperature Support for RSP3 Modules
The router supports multiple fan trays with different cooling capacities. The maximum operating temperature
of the router using the RSP3 modules, depends on the fan tray and the interface modules used in the router.
Cisco ASR 902 and ASR 902U Aggregation Services Router Hardware Installation Guide
34
Overview