Details
Data Type
Total run-time since initial installation. This is based
on the local router clock with a granularity of 30
minutes.
Run-time
Event-Driven Data Collection
Event driven data include card failure events. Failure events are card crashes, memory errors, ASIC resets,
and similar hardware failure indications.
Details
Data Type
Inlet and hot point temperature
value change beyond the threshold
set in the hardware inventory XML
files.
Temperature Value
Environmental Factors
+5, and MBUS +5, +3.3, and +2.2
voltage value.
Voltage Value
An environmental reading is
logged when the following
temperature or voltage events
occur:
•
Exceed the normal range
•
Change more than 10%
•
Return within range for more
than five minutes.
On reboot, these environmental
readings are consolidated into a
single environmental history record
that shows the duration and extent
out of normal range for a
consecutive set of environmental
readings.
Cisco ASR 9000 Series Aggregation Services Router System Monitoring Configuration Guide, Release 4.2.x
313
Onboard Failure Logging
Data Collection Types