You mount only one ASA 5506H-X in the rack-mount shelf.
The dimensions of the ASA 5506H-X are 3.46 in. x 18.3 in. x 19.5 in. (8.79 cm x 46.48 cm x 49.52 cm).
The PID is asa5506h-rack-mnt=.
Note
Step 1
Place the ASA upside down on a large, stable work area. If you are installing two ASAs in the shelf, place the second
ASA beside the first, also upside down.
Step 2
Invert the sliding trays and position the ASA(s) on top of them such that the front of the device(s) and the front of the
tray are in the same direction.
Step 3
Adjust the position of the first ASA and the tray until the three mounting holes in the dimples in the bottom of the shelf
are aligned with the mounting holes in the bottom of the ASA.
Step 4
Tighten the captive tray screws into the shelf to lock it into place.
Figure 23: ASA 5506-X and ASA 5506W-X in the Rack-Mount Shelf
Figure 24: ASA 5506H-X in the Rack-Mount Shelf
Cisco ASA 5506-X, ASA 5506W-X, and ASA 5506H-X Hardware Installation Guide
Online Only
33
Mount and Connect
Rack Mount the ASA