21
Note
If you will be using a streetlight power tap adapter, position the access point within
3 ft (1 m) of the outdoor light control. The AC/DC adapter must be used with street
light power tap.
Step 2
Determine which size of band clamp is needed based on the pole diameter. Slide the two
clamps through the top and bottom set of of mounting slots (see
Figure 9
) and mount the
bracket to the pole.
Step 3
Wrap the band clamps around the pole and slide them into the second set of top and bottom
mounting slots on the bracket. Lightly tighten the clamps. Only tighten them enough to keep
the bracket from sliding down the pole.
Step 4
Screw an M6 bolt into each of the four bolt holes on the back side of the access point. Do not
screw the bolt in all the way. Leave a gap of about 0.13" (3.3mm).
Step 5
Position the four bolts on the access point into the bracket keyhole slots. Check to be sure that
the access point is properly seated in the slots.(See
Figure 9
)
Note
The access point should be positioned with the LEDs on the bottom to allow viewing
from the ground.
Step 6
Using a 10mm wrench, tighten the four bolts that connect the access point to the bracket to
a torque of 40 in-lbf.
Step 7
Locate the access point to its final position. Tighten the band clamps with the wrench so that
the access point does not slide on the pole. Be sure that the clamps are tight enough that the
AP does not move.
Step 8
Continue with the
Grounding the Access Point, page 23
.