29
Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
78-18269-04
Mounting the Access Point
Note
The access point must be installed on a cable strand by a professional cable installer.
To mount the access point preform these steps:
Step 1
Install two cable clips, a flat washer, and a M8 flange nut on each clamp support bolt on the front of the
clamp bracket (see
Figure 16
). You should only hand-tighten the nuts sufficiently to prevent them from
falling off.
Figure 16
Clamp Bracket with Cable Clamps
Step 2
Attach the strand bracket to the access point using two M8 x16 bolts (with flat and lock washers) on each
side of the access point (see
Figure 17
). Only hand-tighten the bolts.
Note
When attached to the cable strand, the access point must be vertically adjusted before the final
tightening of the bolts.
1
Cable strand bracket
2
Two cable clamps, flat washer, and M8 flange nut.