41
Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
78-18269-04
Connecting a Fiber-Optic Cable to the Access Point
Step 2
Open the hinged cover (see the
“Opening the Access Point Hinged Cover” section on page 36
for
instructions).
Step 3
For cable strand deployments, remove the SCTE 5/8 plug (item 1 in
Figure 26
) using a 13 mm wrench
or socket. For all other deployments, remove the fiber-optic connector plug (item 5 in
Figure 26
) using
an adjustable wrench, the 22 mm socket, or the Sealcon S-22-WR wrench.
Step 4
Place the two large reels with the small reels on top as shown in
Figure 26
.
Step 5
Align the screw holes in the large and small reels, and insert four attachment screws in each of the reel
pairs. Tighten the screws to 3 to 4 in. lbs (0.34 to 0.45 Nm).
Step 6
Remove the plug from the end of the SFP module, and insert the module into the SFP receptacle (see
Figure 26
).
Figure 26
Fiber-Optic Cable Components
1
SCTE 5/8 plug
4
Four screws for each reel assembly
2
SFP module slot
5
Fiber-optic connector plug
3
Fiber reels (large reel with small reel on top)