Preparing
to
Make
Connections
Table
2-1
RS-232
Speed
and Distance
Limitations
Data Rate
Baud
Distance
Feet
Distance
Meters
2400
200
60
4800
100
30
9600
50
15
19200
25
7.6
38400
12
3.7
Note
RS-232
is
often used
in violation of these specifications
if
you
understand
the
electrical
problems
that
can
arise
and can
compensate
for
them
you might be
able
to
get
good
results
at
distances greater than those
shown
in
Table
2-1 however
do
so
at
your
own
risk
We
recommend
that
you
stay within
the
standard-defined
distance
Interference
Considerations
When
you
run cables
for
any
significant
distance in an electromagnetic
field interference
can occur
between
the
field
and the
signals
on
the
cables
This
fact
has
two
implications
for the construction
of terminal plant cabling
Plant cabling can
emanate
radio interference
if
it is
unshielded
for too long
distance
Strong
electromagnetic
interference
especially
as
caused
by
lightning or radio transmitters can
destroy the
RS-232
drivers
and
receivers
in
the server
if
you
use twisted-pair cables
in
your plant cabling with
good
distribution
of grounding
conductors
the plant cabling
is
unlikely
to
emit radio interference
When
exceeding
the distances
listed
in
Table
2-1 ground
the conductor
for each
data signal
If
you have
cables
exceeding
the
distances
in
Table
2-1
or
if
you have
cables
that
pass
between
bl4ildings then give special consideration
to
the
effect
of lightning
strikes
or
ground loops The
electromagnetic
pulse caused
by
lightning or other high-energy
phenomena
can
easily
couple
enough
energy
into
unshielded
conductors
to
destroy electronic
devices
If
your
site
has experienced
problems
of
this
sort consult
experts
in
lightning suppression
and
shielding
Most
data centers cannot
resolve the infrequent but potentially catastrophic
problems
just
described
without
pulse meters
and
other special
equipment
Take
precautions
to
avoid
these
problems by
providing
properly
grounded and
shielded
environment
with
special
attention
to
issues of
electrical
surge suppression
To
predict
and remedy
strong electromagnetic
interference
consult experts
in
RFI
2-10
Cisco 3000 Hardware
Installation
and Maintenance
Summary of Contents for 3000 Series
Page 1: ...cIscoSsoToMo ...
Page 7: ...vi Cisco 3000 Hardware Installation and Maintenance ...
Page 11: ...Cisco 3000 Hardware Installation and Maintenance ...
Page 67: ...Recovering Lost Password 5 20 Cisco 3000 Hardware Installation and Maintenance ...
Page 81: ...Ethernet Cable Assembly A 14 Cisce 3000 Hardware Installation and Maintenance ...
Page 87: ...Virtual Configuration Register Settings B fl Cisco 3000 Hardware Installation and Maintenance ...
Page 93: ...For United Kingdom Use Only D 2 Cisco 3000 Hardware Installation and Maintenance ...
Page 95: ...For European Community Use Only E 2 Cisco 3000 Hardware Installation and Maintenance ...