![Cisco 2948G - Catalyst Switch Configuration Manual Download Page 241](http://html.mh-extra.com/html/cisco/2948g-catalyst-switch/2948g-catalyst-switch_configuration-manual_67462241.webp)
11-11
Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide
—
Release 8.1
78-15486-01
Chapter 11 Configuring VLAN Trunks on Fast Ethernet and Gigabit Ethernet Ports
Example VLAN Trunk Configurations
2/3 1-1005, 1025-4094
2/4 1-1005, 1025-4094
2/5 1-1005, 1025-4094
2/6 1-1005, 1025-4094
Port Vlans in spanning tree forwarding state and not pruned
-------- ---------------------------------------------------------------------
2/3 1-1005, 1025-4094
2/4 1-1005, 1025-4094
2/5 1-1005, 1025-4094
2/6 1-1005, 1025-4094
Switch_A> (enable)
Switch_B> (enable) show trunk
Port Mode Encapsulation Status Native vlan
-------- ----------- ------------- ------------ -----------
3/3 auto dot1q trunking 1
3/4 auto dot1q trunking 1
3/5 auto dot1q trunking 1
3/6 auto dot1q trunking 1
Port Vlans allowed on trunk
-------- ---------------------------------------------------------------------
3/3 1-1005, 1025-4094
3/4 1-1005, 1025-4094
3/5 1-1005, 1025-4094
3/6 1-1005, 1025-4094
Port Vlans allowed and active in management domain
-------- ---------------------------------------------------------------------
3/3 1-1005, 1025-4094
3/4 1-1005, 1025-4094
3/5 1-1005, 1025-4094
3/6 1-1005, 1025-4094
Port Vlans in spanning tree forwarding state and not pruned
-------- ---------------------------------------------------------------------
3/3 1-1005, 1025-4094
3/4 1-1005, 1025-4094
3/5 1-1005, 1025-4094
3/6 1-1005, 1025-4094
Switch_B> (enable)
Step 4
Confirm the channeling and trunking status of the switches by entering the show port channel and show
trunk commands.
Switch_A> (enable) show port channel
No ports channelling
Switch_A> (enable) show trunk
No ports trunking.
Switch_A> (enable)
Switch_B> (enable) show port channel
No ports channelling
Switch_B> (enable) show trunk
No ports trunking.
Switch_B> (enable)
Step 5
Configure the ports on Switch A to negotiate a Gigabit EtherChannel bundle with the neighboring
switch. This example assumes that the neighboring ports on Switch B are in EtherChannel auto mode.
The system logging messages provide information about the formation of the EtherChannel bundle.