1-4
Cisco 2600 Series Routers Hardware Installation Guide
OL-2171-02
Chapter 1 Overview of Cisco 2600 Series Routers
System Specifications
Input voltage, DC power supply
Current
Power dissipation
–38 to –75 VDC
2.0A
75W (maximum), 260 Btus/hr
Processor:
Cisco 261xx routers
Cisco 262xx routers
Cisco 265xx routers
Cisco 261xxXM routers
Cisco 262xxXM routers
Cisco 265xxXM routers
40-MHz Motorola PowerQUICC MPC860
50-MHz Motorola PowerQUICC MPC860
80-MHz Motorola PowerQUICC MPC860P
40-MHz Motorola PowerQUICC MPC860P
50-MHz Motorola PowerQUICC MPC860P
80-MHz Motorola PowerQUICC MPC860P
Operating environment
32 to 104
°
F (0 to 40
°
C)
Nonoperating temperature
–40 to 158
°
F (–40 to 70
°
C)
Operating humidity
5 to 95 percent, noncondensing
Noise level
38 dBa (minimum)
Regulatory compliance
FCC Class B and Canadian DOC Class A
For more regulatory information, refer to the Regulatory
Compliance and Safety Information document that
accompanied your router.
1.
Btus = British thermal units
Table 1-3
Cisco 2691 System Specifications
Description
Specification
Dimensions (H x W x D)
3.46 x 17.07 x 11.20 in. (8.78 x 45.36 x 28.45 cm),
two rack unit in height
Weight
15 lb (6.80 kg)
Input voltage, AC power supply
Current emissions (AC)
Frequency
Line surge (120 VAC)
Line surge (240VAC)
100 to 120, 120 VAC
200 to 240, 230 VAC
0.93 min. @ 120VAC 60Hz (when loaded at 50% or
higher
47 to 63 Hz
160 VAC - 1/2 cycle
140 VAC - 5 cycles
320 VAC - 1/2 cycle
280 VAC - 5 cycles
Power dissipation
105W (maximum)
Processor
240-MHz PMC-Sierra RM7061A RISC processor
Console and Auxiliary ports
RJ-45 connector
Operating humidity
5 to 95%, noncondensing
Operating temperature
32 to 104
°
F (0 to 40
°
C)
Nonoperating temperature
–40 to 158
°
F (–40 to 70
°
C)
Table 1-2
Cisco 261x, Cisco 262x, and Cisco 265x System Specifications (continued)
Description
Specification