Chapter 2 Cabling and Troubleshooting the CSS
Troubleshooting the CSS Hardware Components
2-40
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-16421-01
Troubleshooting the CSS Modules
CSS 11503 and CSS 11506 module status is indicated by the Status LED on the
module front panel. For information about the module LEDs, see the
“Cabling the
CSS 11503 and CSS 11506 Modules”
section earlier in this chapter.
Table 2-12
provides suggestions for correcting problems that may occur with the
modules in the CSS 11503 and CSS 11506.
Caution
Always power down the CSS prior to removing or installing a module.
During normal CSS operation,
the following message appears:
Temperature has reached
x
celsius for slot
number
Check the six fans in the chassis. The
CSS 11501 is running at a temperature that is
too high, as indicated by the
x
variable. When a
fan failure occurs, obtain technical assistance.
You cannot access log or
archive files on the CSS disk but
traffic is still passed in and out
of the CSS.
Replace the disk containing the files. Remove
the disk and install the replacement in the
CSS 11501. Refer to the reference sheet that
comes with the replacement disk.
After you install the disk in the CSS, you must
wait 10 seconds before you can reseat or
remove it.
If the replacement disk does not have the same
software version that the CSS is running, the
CSS 11501 will not initialize the disk. You
must reboot the CSS and configure a primary
boot record. You can select the CSS software
currently on the disk or instruct the CSS where
to locate the CSS software ADI file to install on
the disk. If you archived an offline version of
your CSS running-config file, copy it back onto
the CSS.
Table 2-11
Troubleshooting the CSS 11501 (continued)
Symptom
Recommended Action