2-39
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-16421-01
Chapter 2 Cabling and Troubleshooting the CSS
Troubleshooting the CSS Hardware Components
Troubleshooting the CSS 11501
CSS 11501 status is indicated by the Status LED on the front panel. For
information about the CSS 11501 LEDs, see the
“Cabling the CSS 11501”
section
earlier in this chapter.
Table 2-11
provides suggestions for correcting problems that may occur with the
CSS 11501.
Table 2-11
Troubleshooting the CSS 11501
Symptom
Recommended Action
At boot up, the following
message appears:
CHMGR: Slot
slot
/
subslot
had diagnostic failures -
NOT STARTING UP
When there is a failure on a CSS 11501
component, the CSS 11501 attempts the boot
process three times. If the boot is unsuccessful,
the CSS generates a log message and saves it in
the boot.log file. Obtain technical assistance.
Refer to
“Preface”
. For information on log
files, refer to the
Cisco Content Services Switch
Administration Guide
.