VCC-F60U29GE
Rev.900-682-30-00
©2008 CIS Corporation. All rights reserved.
16
8. Partial Scan Mode Details
Capturing start position and capturing width can be set by 3H via LAN.
LVAL Output
(Normal Scan)
9 H
Video Output
(Normal Scan)
1252 H
VIDEO Output
(Partial Scan)
LVAL Output
(Partial Scan)
9 H
19 H
Total Line(Address 021&022) + 1H
1224 H
Y Offset
19H + Starting Position
(Address016&017)
Effective Line
(Address 019&020)×3+3H
High Speed
Transmit Term
High Speed
Transmit Term
Reading out position register (Address 016 & 017): 0(0H)
~
407 (1221H)
3H/step
Effective line register (Address 019 & 020): 0(3H)
~
407 (1224H) 3H/step
Total line register (Address 021 & 022): 435H + (Effective line register × 2) + 2 (Read Only)
Note: Reading out position and effective line shall meet the following condition.
Reading out position re Effective line register = < 407
Otherwise, the value, 407 – reading out position register, will be set to the effective line register.
<Example 1>
Conditions: Reading out position register (Address 016 & 017) = 000
Effective line register
(Address 019&020)
Effective Lines
Total Line register
+
1H
Frame Rate
RAW mode
RGB mode
0
3 H
438 H
76 fps
38 fps
・
・
・
・
・
159
480 H
756 H
44 fps
・
22
fps
・
・
・
・
・
・
255
768 H
948 H
35 fps
18 fps
・
・
・
・
・
341
1026 H
1120 H
30 fps
15 fps
・
・
・
・
・
407 1224
1252 H
27 fps
13 fps