900-525-31-00
15
HD sync input is enabled.
Jitter between Int. HD and Trigger will cause 1HD fluctuation in exposure time.
To avoid this fluctuation, please synchronize with EXT. HD. Note that the trigger pulse width must be
over 1 HD.
7.1.3. Partial Scan Setting Switch (Rear Panel SW: 6 SCAN)
SCAN
Scanning mode
V Scanning lines
Rate
V Effective lines
OFF
Full pixels
1068 Lines
38 fps
1024 Lines
ON
Partial scan mode
550 Lines
73 fps
258 Lines
Partial scan is the mode, which increases the frame rate by reducing the number of read-out vertical lines.
The upper part and the lower part of the image are omitted, and only the central portion of the vertical
lines is read out. When gain is set at over +6dB, V shading may become visible.
V-Shading portion can be deleted by setting data “1” to address 057 which eliminates the top 35 lines.
Effective lines setting and readout position in partial scan mode
(1) In partial scan mode, effective lines and readout position can be set with remote control.
(a) Effective lines setting: By setting address 049, 255 line to 681 line can be set per 3 lines steps.
Address 049
Set value
Effective lines
TOTAL Lines
(Address 052&053:Read
only
)
Frame Rate
0 255 548
73fps
1 258 550
73fps
・
・
・
・
・
・
・
・
・
・
・
・
142 681 832
48fps
↓ ↓ ↓
X: min0
〜
max142
255+3*X 548+2*X
(b) Readout position setting: By setting address 051, every 3 lines steps can be set from the top.
Address 051
Min 0
〜
Max258-X (address 049)
<
Setting example
>
Q
.
Need to readout effective 600 vertical lines from the
300
th
line.
A
.
(1) address 000:1
・・・
Remote control
(2) address 005:1
・・・
Partial SCAN mode
(3) address 049:115
・・・
Effective line setting((600-255)/3)
(4) address 051:100
・・・
Readout position setting (300/3)
(5) address 063:83
・・・
Data saving (If necessary)
(Camera internal SW104-2 shall be ON to save data)
(d). Partial Scan Timing