Shutter Speed Settings   

 

(At 30fps Mode)

 

ES2  ES1  ES0  Shutter Speed 

Actual Time 

SW1  SW2  SW3   

Normal Shutter 

Trigger Shutter 

OFF  OFF  OFF 

OFF (1/30s) 

33.4 ms   

10.0 ms 

OFF  OFF  ON 

1/125 s 

8.1 ms 

8.1 ms 

OFF  ON 

OFF 

1/250 s 

4.0 ms 

4.0 ms 

OFF  ON 

ON 

1/500 s 

2.0 ms 

2.0 ms 

ON 

OFF  OFF 

1/1000 s 

986 μs 

982 μs 

ON 

OFF  ON 

1/2000 s 

478 μs 

478 μs 

ON 

ON 

OFF 

1/4000 s 

225 μs 

225 μs 

ON 

ON 

ON 

1/10000 s 

98 μs 

98 μs 

 

(At 60fps Mode)

 

ES2  ES1  ES0  Shutter Speed 

Actual Time 

SW1  SW2  SW3   

Normal Shutter 

Trigger Shutter 

OFF  OFF  OFF 

OFF (1/60s) 

16.7 ms   

5.0 ms 

OFF  OFF  ON 

1/250 s 

4.0 ms 

4.0 ms 

OFF  ON 

OFF 

1/500 s 

2.0 ms 

2.0 ms 

OFF  ON 

ON 

1/1000 s 

1.0 ms 

1.0 ms 

ON 

OFF  OFF 

1/2000 s 

493 μs 

494 μs 

ON 

OFF  ON 

1/4000 s 

239 μs 

240 μs 

ON 

ON 

OFF 

1/8000 s 

113 μs 

113 μs 

ON 

ON 

ON 

1/20000 s 

49 μs 

49 μs 

                Indicates initial setting position 

 

 

CCD Charge Storage Mode Settings   

SW4 

OFF  FLD 

Field Storage 

 

ON 

FRM 

Frame Storage 

                Indicates initial setting position 

 

 

Shutter Mode Settings 

Mode2  Mode1 

Mode0  Setting Mode 

SW5  SW6  SW7 

 

OFF     

 

 

     

 

OFF 

OFF 

Normal Shutter Mode 

OFF 

ON 

ON 

Restart/Reset Mode 

ON 

OFF 

OFF 

Fixed Trigger Shutter Mode (SYNC Reset Mode) 

ON 

OFF 

ON 

〃           

(SYNC Non Reset Mode) 

ON 

ON 

OFF 

Pulse Width Trigger Shutter Mode (SYNC Reset Mode) 

ON 

ON 

ON 

〃           

(SYNC Non Reset Mode) 

                Indicates initial setting position 

 

Summary of Contents for VCC-G20E20B

Page 1: ...VCC G20E20B Rev 900 710 35 2014 CIS Corporation All rights reserved Analog I F 29mm Cubic EIA Analog B W Camera VCC G20E20B Product Specification Operational Manual CIS Corporation English...

Page 2: ...Input Output Signal Specification 7 4 3 CCD Spectral Response Representative value 8 5 Function Settings 8 6 External Connector Pin Assignment 14 7 Timing Chart 14 7 1 Horizontal Sync Timing 14 7 2 V...

Page 3: ...ic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration Do not ap...

Page 4: ...HD VD sync input or Trigger input are valid 1 100s 1 10 000s 8 steps shutter speed can be set by rear switch as fixed trigger shutter 100 s 250ms shutter speed can be set by trigger pulse width as pu...

Page 5: ...LK Vertical Frequency 1 60s 2 1 Interlaced 59 94 Hz Scanning lines 525H 1 120s Non Interlaced 119 9 Hz Scanning lines 262 5H Sync system Internal sync HD VD external sync Internal External recognized...

Page 6: ...standards UL Conform to UL Standard including materials and others RoHS Conform to RoHS CE Conform to EN55022 2006 Class B for Emmission Conform to EN61000 6 2 2005 for Immunity FCC FCC Class A digit...

Page 7: ...difference HD VD under 0 5 s Jitter under 20ns HD VD 75 10K SW 100 4 7K 33K 47pF 3 3V IN OUT CMOS 5V WEN output CMOS 74VHC04 equivalent Output impedance 100 HD VD WEN output signal level Low 0 5V max...

Page 8: ...Shutter Speed 8 steps At 30fps OFF 1 30s 1 10000s At 60fps OFF 1 60s 1 20000s Field Frame 2 ES1 3 ES0 4 FLD FRM 5 Mode2 Shutter Mode Normal Shutter Mode Restart Reset Mode Trigger Shutter Mode 6 Mode1...

Page 9: ...OFF OFF OFF OFF 1 60s 16 7 ms 5 0 ms OFF OFF ON 1 250 s 4 0 ms 4 0 ms OFF ON OFF 1 500 s 2 0 ms 2 0 ms OFF ON ON 1 1000 s 1 0 ms 1 0 ms ON OFF OFF 1 2000 s 493 s 494 s ON OFF ON 1 4000 s 239 s 240 s O...

Page 10: ...de field Field Frame Shutter Speed Settings by rear switch Shutter Speed Settings by trigger pulse width HD VD Input HD VD Output Normal Shutter Mode At normal shutter mode consecutive video signals a...

Page 11: ...1 2H Internal VD Composite Sync and WEN signals are one to one correspondence to trigger input so that capturing images can be done with any output signals HD VD sync signals are not necessary basica...

Page 12: ...gnals are read out after 1 2H Internal VD Composite Sync and WEN signals are one to one correspondence to trigger input so that capturing images can be done with any output signals HD VD sync signals...

Page 13: ...volume of incident light or use a stroboscopic light source to control the light volume Caution 3 Please refer to the exposure timing chart below for 30fps mode for the actual timing to start exposur...

Page 14: ...c Timing Pin No 1 GND 2 Power In DC 12V 3 GND 4 Video Out 5 GND 6 HD In Out 7 VD In Out 8 GND 9 N A 10 WEN Out 11 Trig In 12 GND Camera HD CCD Output 91 Black Transmit Dummy Pixels 40 77 25 1 768 Effe...

Page 15: ...9 10 493 494 491 492 WEN Output 20H Vertical Blanking 20H Video Active Period 242 5H 10H 10H EVEN Field 262 5H 494 CCD Output Black Transmit 8 6 2 9 247 Effective Lines ODD Field 262 5H 247 1 6 Effec...

Page 16: ...The center of effective pixels shall be within f 0 6 to the center of lens mount Inclination of effective pixels Theta to datum plane shall be 0 5 Dimension from datum plane to the center of lens moun...

Page 17: ...VCC G20E20B Rev 900 710 35 2014 CIS Corporation All rights reserved 17 9 Dimensions...

Page 18: ...alfunction or non function of the equipment we shall be exempted from responsibility for such damages In case damage or losses are caused by failure to observe the information contained in the instruc...

Page 19: ...e products The cause of the CCD pixel defects is the characteristic phenomenon of CCD itself and CIS shall be exempted from taking responsibility on it 12 Product Support When defects or malfunction o...

Reviews: