VCC-2CXP6R
Rev.905-0187-02
©2019 CIS Corporation. All rights reserved.
11
TriggerMode
: Trigger mode
On
: Validate the trigger selected by TriggerSource. (TriggerSelector = FrameStart)
Off
: Invalidate the trigger selected by TriggerSource. (TriggerSelector = AcquisitionStart)
※ Please do not change TriggerMode while grabbing (acquiring image).
TriggerSyncMode : Trigger sync. mode
LineSync
: H sync. trigger mode (Exposure time is controllable per line)
Fixed/Pulse width trigger shutter mode
Overlapping operation (Exposure while reading out image) is valid.
ClockSync
: CLK sync. trigger mode (Exposure time is controllable per sensor clock)
FAST fixed/FAST pulse width trigger shutter mode
Overlapping operation (Exposure while reading out image) is invalid.
※ Please change TriggerSyncMode while there is no trigger input.
※ Please set Free run mode (internal sync. mode) after set itself to LineSync mode.
TriggerSelector : Trigger selector
This is to select how to start capturing the image and to select the polarity out of following.
AcquisitionStart
: Free run mode [Internal sync. mode]
FrameStart
: External trigger mode
※
Please do not change TriggerSelector while grabbing (acquiring image).
TriggerActivation
: Trigger activation
This is to select how to start capturing the image and to select the polarity out of following.
RisingEdge
: Fixed trigger shutter mode: Rising edge (Timed)
FallingEdge
: Fixed trigger shutter mode: Falling edge (Timed)
LevelHigh
: Pulse width trigger shutter mode: High active (TriggerWidth)
LevelLow
: Pulse width trigger shutter mode: Low active (TriggerWidth)
TriggerSource
: Trigger source
This is to select where to input the external trigger.
Software
: TriggerSoftware
LinkTrigger0 : External trigger input from CoaXPress Host Device
Please refer to the product specifications & operational manual of the Host Device
(ex. grabber board) to use for how to generate the trigger.
Line0
: Input the external trigger via 6pins circular connector.
TriggerSoftware
: Software trigger
A trigger is generated in the camera and capture images for 1 frame when this command is
executed. Please make sure to set TriggerSource to Software.
※ Software Trigger is valid at Rising Edge.