![CIS iVISION Security VCC-V90S Product Specification & Operation Manual Download Page 11](http://html1.mh-extra.com/html/cis/ivision-security-vcc-v90s/ivision-security-vcc-v90s_product-specification-and-operation-manual_2608736011.webp)
VCC-V90S Rev.900-625-30-00
I/O ports
Output is set as Open collector (+5V PULL UP 10K
Ω
)(Max.20mA, Max.+5.5V)
Input is set as Emitter Follower (+5V PULL UP 10K)(Max.20mA,Max.+5.5V)
At the time of input, set connector OPEN to identify “1”, and connect between a connector and GND as short or
less than 1K
Ω
to identify “0”.
2
1
5
4
6
3
10K
B
C
E
4.7K
5.6K
2.2K
470
10K
10K
22
1
2
UDZ15B
2.2K
270NH
P
030
0S
A
L
(25V
/150A
)
©2008 CIS Corporation. All rights reserved.
11
I/O Port
+5V
OUT
IN
GND
Camera
100K
Output for Electric lens
This connector controls zoom/focus for the Electric lens
TELE+,- : The voltage difference b and - connectors occurs when electric
zoom command is issued.
If change to oppoite direction, the voltage difference direction also
changes.
When stops, the pressure becomes 0.
No load operation: +,- connector pressure: 7V
220
Ω
load operation: +,- connector pressure: 6.7V
FAR+,- : The voltage difference b and – connectors occurs when electric
focus command is issued.
If change to oppoite direction, the voltage difference direction also
changes.
When stops, the pressure becomes 0.
No load operation: +,- connector pressure: 7V
220
Ω
load operation: +,- connector pressure: 6.7V
⑦
MIC IN connector
Input connector for audio.
Plug-in power standard microphone can be connected. (2.5V)
Can be used as a LINE IN
Please use 3.5 monaural mini plug for input
Camera side uses a stereo mini jack, however, please use monaural mini plug
⑧
LINE OUT connector
Output connector for audio
Please use 3.5 monaural mini plug for output