Cirronet SEM2410 User Manual Download Page 7

 

 2000, 2001  Cirronet

 Incorporated 

4

 M-2410-0007 Rev - 

The network that the SEM is connecting to must be compatible with 10BaseT products.  
The SEM 

will not

 work if the network only supports 100BaseT or half duplex 10BaseT 

products.  Before connecting a default configured SEM to an active network that does not 
have a BOOTP or DHCP server, ask the network system for an IP address for the SEM 
that will not cause any problems on the network.  

The SEM can be configured two ways.  The first is through the serial port.  The settings 
for the serial port are 38400 baud, 8 data bits, 1 stop bit, and no parity. SEMcom will 
automatically find the appropriate serial port and configure the serial port settings for 
you.  The software will inform you of its progress and any problems that arise.  After a 
few seconds the SEM firmware version is displayed followed by the 

SEM>

 prompt. 

To set the IP number of the SEM, use the 

ip

 command. 

ip <xxx.xxx.xxx.xxx> {yyy.yyy.yyy.yyy}

 

Where x is the new IP address, and y is the optional netmask number.  

Once a valid IP address has been entered in the SEM, a second method to configure the 
SEM is through a telnet session.  Most telnet programs work with the SEM.  Windows 
95/98/NT/2000/ME have a telnet program that works with the SEM.  A telnet session can 
be started by clicking on Start->Run if you have Windows 95/98/NT/2000 and the 
TCP/IP client has been installed.  For a SEM with an IP address of 192.168.0.254, enter 
the following information in the dialog box: 

telnet 192.168.0.254 

A telnet window will open up. The first line is the version of the SEM firmware followed 
by the prompt: 

SEM> 

If the SEM is to transmit data to devices not on its subnet, a default router must be 

specified. To enter the default routing address use the 

route

 command. 

  

route add default <xxx.xxx.xxx.xxx> {yyy.yyy.yyy.yyy} 

Where x is the IP address of the gateway device and y is the optional netmask number. 

To configure a SEM as a master device, use the 

bridge

 command: 

 

bridge master<CR>

 

The SEM2410 includes provision for filtering of multicast and broadcast packets. In 

many networks, there is sufficient multicast and/or broadcast packets to slow the overall 
performance of the SEM. By turning filtering on, the SEM will ignore these packets and 
limit transmission to packets with specific device addresses. In some instances, it will be 
desired to have the SEM transmit the multicast and broadcast packets; in this instance 
filtering should be disabled. Note that filtering broadcast packets also filters multicast 
packets but filtering multicast packets does not filter broadcast packets. To filter 
broadcast and multicast packets use the bridge filter command: 

  

bridge filter bcast<CR> 

Refer to the section 

SEM/Radio Commands

 for details of the filter commands. 

Summary of Contents for SEM2410

Page 1: ...SEM2410 Wireless Ethernet Modem Bridge User s Manual October 17 2001 5375 Oakbrook Parkway Norcross Georgia 30093 www cirronet com 678 684 2000...

Page 2: ...and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a r...

Page 3: ...Mode 6 Point to Mulitpoint Mode 6 TCP IP Addresses 8 Filtering 8 DHCP 8 SEM Command Set 10 Ethernet Commands 10 SEM Radio Commands 11 SEM System Commands 13 Radio Modem Configuration 14 Radio Commands...

Page 4: ...he communication between SEM products is performed using the WIT2410 over the air protocol Thus the SEM products are 802 3 compatible but not 802 11 compatible and provide 460Kbps data throughput Cert...

Page 5: ...baseband cable that can be ordered in 100 foot increments up to 500 feet in length The SEM2410X has a 15 pin connector in place of the TNC connector on the SEM2410 The 10BaseT Ethernet connector is t...

Page 6: ...d that the power switch is in the ON position TXD and RXD are indicators of data activity They indicate the transmission and reception of data over the Ethernet connection Note that these LEDs can be...

Page 7: ...rted by clicking on Start Run if you have Windows 95 98 NT 2000 and the TCP IP client has been installed For a SEM with an IP address of 192 168 0 254 enter the following information in the dialog box...

Page 8: ...back the time it took to the save the information Reset the SEM by typing reset CR The SEM can also be reset by cycling power Whenever a reset is executed on the SEM the telnet session will be lost It...

Page 9: ...mote radio When a master SEM is powered on it becomes active immediately even if no slave SEMs are detected It will attempt to send packets addressed to devices that it thinks are not on its local net...

Page 10: ...s the better approach is to pick the hop duration to maximize data throughput without unnecessarily penalizing latency The maximum number of bytes that can be transmitted on a single hop by either a m...

Page 11: ...vices not on its subnet To display the routing table use the route list command There will always be one entry in the routing table that corresponds to the IP address in the SEM For most applications...

Page 12: ...sing the route command See the previous section for details of the route command If an IP address has previously been entered into the SEM but a DHCP server is to be used to assign an IP address it wi...

Page 13: ...Adds IP address and netmask to route list Deletes IP address from route list Lists route IP addresses socks Displays network socket information arp Manipulates the address resolution procedure table T...

Page 14: ...up override Displays synchronization settings Sets SEM as sync slave Sets synchronization mode to use RJ 11 wire ports bridge Selects filtering mode and sets master slave status filter disable turns f...

Page 15: ...rks The default mode is the sync OFF Sync is enabled by selecting a synchronization method ether and wire are mutually exclusive commands and set the synchronization to occur over the Ethernet or over...

Page 16: ...mands Most commands that require a parameter also have a help mode that displays the help screen for that command reset Resets the SEM and loads saved parameters into active memory Also causes the SEM...

Page 17: ...EM Command Description help Displays command list banner Displays power on banner for the radio in the SEM defaults Resets the radio parameters to the factory shipped values maxremotes 0 5 Displays va...

Page 18: ...ptimization parameter should be set in the remote SEMs This parameter is set using the radio a param command with dx as the sub command The dx sub command has a single argument that is a hexadecimal v...

Page 19: ...prompt type radio a param dx 04 CR Save this value by issuing the save command save CR The dx value will take effect immediately It is not necessary to issue a reset command Note that it is possible...

Page 20: ...equency hopping up to 64 user selectable hopping patterns Frequency Range 2400MHz to 2483 5MHz Operating Voltage Range 7VDC to 26VDC Enclosure Ruggedized Aluminum Dimensions 201 x 144 x 53 mm 7 9 x 5...

Page 21: ...router make sure that the correct address has been entered in the routing table The SEM does not respond through the Configuration Port Check that a straight through serial cable is being used if con...

Page 22: ...to the goods such as but not limited to power failure No suit or action shall be brought against Seller more than twelve 12 months after the related cause of action has occurred Buyer has not relied...

Reviews: