3

 M-2410-0007 Rev - 

using an RJ-11 connector. If the sync signals are required, one of the master SEMs must 
be designated as the sync master. See the section 

SEM/Radio 

Commands for details. If 

there are no co-located master SEMs, sync should be left disabled.  

The power connector is a 2-pin DIN type connector. The provided AC adapter provides a 
9 volt power level to the SEM. The SEM can accept DC voltages ranging between 7VDC 
and 26VDC if alternative power supplies are to be used. 

Figure 2. SEM Front Panel Diagram 

The Configuration Port is an RS-232 serial port that may be used to configure the SEM. 
This is useful when the default IP address of the SEM cannot be used with the existing 
network preventing configuration through a telnet session. See the section 

Configuring 

the SEM

 for details of using this port. 

SEM Status Indicators 

The PWR indicator on the front panel indicates that power is applied to the SEM and that 
the power switch is in the ON position. 

TXD and RXD are indicators of data activity. They indicate the transmission and 
reception of data over the Ethernet connection. Note that these LEDs can be active even 
when the SEM is not communicating with another SEM. 

On a slave SEM, the Link A LED indicates the SEM has established a connection with 
the master SEM. When a slave SEM is powered on, it will take a few seconds for this 
LED to turn on. On a master SEM the Link A LED is always on. The Link B LED is not 
used.  

Configuring the SEM 

SEMs are shipped from the factory with default settings that include a default IP address 
of 0.0.0.0 and a default configuration as a slave bridge. In order to set up a wireless link, 
alternate IP addresses need to be assigned and one of  the SEMs must be configured as a 
master device. If a BOOTP or DHCP server is not present a different IP address must be 
assigned to the SEM. If a DHCP server is present on the network, the IP address can be 
set up through it. See the sections 

BOOTP 

and

 DHCP

 for details. 

SEM 2410 

2.4 GHz SPREAD SPECTRUM WIRELESS ETHERNET MODEM 

Power Switch 

Status Indicators 

Configuration Port 

Summary of Contents for SEM2410

Page 1: ...SEM2410 Wireless Ethernet Modem Bridge User s Manual October 17 2001 5375 Oakbrook Parkway Norcross Georgia 30093 www cirronet com 678 684 2000...

Page 2: ...and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a r...

Page 3: ...Mode 6 Point to Mulitpoint Mode 6 TCP IP Addresses 8 Filtering 8 DHCP 8 SEM Command Set 10 Ethernet Commands 10 SEM Radio Commands 11 SEM System Commands 13 Radio Modem Configuration 14 Radio Commands...

Page 4: ...he communication between SEM products is performed using the WIT2410 over the air protocol Thus the SEM products are 802 3 compatible but not 802 11 compatible and provide 460Kbps data throughput Cert...

Page 5: ...baseband cable that can be ordered in 100 foot increments up to 500 feet in length The SEM2410X has a 15 pin connector in place of the TNC connector on the SEM2410 The 10BaseT Ethernet connector is t...

Page 6: ...d that the power switch is in the ON position TXD and RXD are indicators of data activity They indicate the transmission and reception of data over the Ethernet connection Note that these LEDs can be...

Page 7: ...rted by clicking on Start Run if you have Windows 95 98 NT 2000 and the TCP IP client has been installed For a SEM with an IP address of 192 168 0 254 enter the following information in the dialog box...

Page 8: ...back the time it took to the save the information Reset the SEM by typing reset CR The SEM can also be reset by cycling power Whenever a reset is executed on the SEM the telnet session will be lost It...

Page 9: ...mote radio When a master SEM is powered on it becomes active immediately even if no slave SEMs are detected It will attempt to send packets addressed to devices that it thinks are not on its local net...

Page 10: ...s the better approach is to pick the hop duration to maximize data throughput without unnecessarily penalizing latency The maximum number of bytes that can be transmitted on a single hop by either a m...

Page 11: ...vices not on its subnet To display the routing table use the route list command There will always be one entry in the routing table that corresponds to the IP address in the SEM For most applications...

Page 12: ...sing the route command See the previous section for details of the route command If an IP address has previously been entered into the SEM but a DHCP server is to be used to assign an IP address it wi...

Page 13: ...Adds IP address and netmask to route list Deletes IP address from route list Lists route IP addresses socks Displays network socket information arp Manipulates the address resolution procedure table T...

Page 14: ...up override Displays synchronization settings Sets SEM as sync slave Sets synchronization mode to use RJ 11 wire ports bridge Selects filtering mode and sets master slave status filter disable turns f...

Page 15: ...rks The default mode is the sync OFF Sync is enabled by selecting a synchronization method ether and wire are mutually exclusive commands and set the synchronization to occur over the Ethernet or over...

Page 16: ...mands Most commands that require a parameter also have a help mode that displays the help screen for that command reset Resets the SEM and loads saved parameters into active memory Also causes the SEM...

Page 17: ...EM Command Description help Displays command list banner Displays power on banner for the radio in the SEM defaults Resets the radio parameters to the factory shipped values maxremotes 0 5 Displays va...

Page 18: ...ptimization parameter should be set in the remote SEMs This parameter is set using the radio a param command with dx as the sub command The dx sub command has a single argument that is a hexadecimal v...

Page 19: ...prompt type radio a param dx 04 CR Save this value by issuing the save command save CR The dx value will take effect immediately It is not necessary to issue a reset command Note that it is possible...

Page 20: ...equency hopping up to 64 user selectable hopping patterns Frequency Range 2400MHz to 2483 5MHz Operating Voltage Range 7VDC to 26VDC Enclosure Ruggedized Aluminum Dimensions 201 x 144 x 53 mm 7 9 x 5...

Page 21: ...router make sure that the correct address has been entered in the routing table The SEM does not respond through the Configuration Port Check that a straight through serial cable is being used if con...

Page 22: ...to the goods such as but not limited to power failure No suit or action shall be brought against Seller more than twelve 12 months after the related cause of action has occurred Buyer has not relied...

Reviews: