Cirronet SEM2410 User Manual Download Page 5

 

 2000, 2001  Cirronet

 Incorporated 

2

 M-2410-0007 Rev - 

Getting Started 

The SEM family of wireless Ethernet modems are easy to install and operate. In most 
instances, the only installation steps will be setting IP addresses, selecting one modem as 
the master and connecting the antenna, power and Ethernet cable. 

Connecting the SEM 

Figure 1 identifies the various connectors on the rear of the SEM.  

Figure 1. SEM Rear Panel Diagram 

The antenna connector is a TNC type connector. An antenna may be connected directly 
to this connector. Alternatively, an antenna may be located away from the SEM using RF 
cable to connect the SEM to the antenna. Cirronet does not recommend using RF cables 
longer than 5 feet. If more distance is required between the SEM and the antenna, high-
quality, low-loss RF feed line must be used. Alternatively, the SEM2410X has a remote 
radio assembly that is mounted next to the antenna. The remote radio assembly is 
connected to the SEM through a baseband cable that can be ordered in 100 foot 
increments up to 500 feet in length. The SEM2410X has a 15 pin connector in place of 
the TNC connector on the SEM2410. 

The 10BaseT Ethernet connector is the standard RJ-45 connector. The connector is wired 
to be able to connect directly to an Ethernet device using a straight-through cable without 
having to connect through a hub. If it is desired to connect the SEM to a hub, the SEM 
must be connected to the Uplink port of the hub to use a straight-through cable. 
Otherwise a cross-over cable is needed to connect a SEM to a hub. The Ethernet 
connector has two LEDs built in. The green LED on the left indicates a good Ethernet 
connection. The yellow LED on the right indicates network collisions. When the yellow 
LED is on continuously, it indicates that there is sufficient network congestion to impact 
data throughput. 

The synchronizing signals are provided for special applications where multiple master 
SEMs are co-located. The synchronizing signals are RS-485 levels and may be connected 

Power Connector 

Synchronizing Signals 

10BaseT Ethernet Connector 

TNC Antenna Connector 

Ethernet Link 

Ethernet Collision 

Summary of Contents for SEM2410

Page 1: ...SEM2410 Wireless Ethernet Modem Bridge User s Manual October 17 2001 5375 Oakbrook Parkway Norcross Georgia 30093 www cirronet com 678 684 2000...

Page 2: ...and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a r...

Page 3: ...Mode 6 Point to Mulitpoint Mode 6 TCP IP Addresses 8 Filtering 8 DHCP 8 SEM Command Set 10 Ethernet Commands 10 SEM Radio Commands 11 SEM System Commands 13 Radio Modem Configuration 14 Radio Commands...

Page 4: ...he communication between SEM products is performed using the WIT2410 over the air protocol Thus the SEM products are 802 3 compatible but not 802 11 compatible and provide 460Kbps data throughput Cert...

Page 5: ...baseband cable that can be ordered in 100 foot increments up to 500 feet in length The SEM2410X has a 15 pin connector in place of the TNC connector on the SEM2410 The 10BaseT Ethernet connector is t...

Page 6: ...d that the power switch is in the ON position TXD and RXD are indicators of data activity They indicate the transmission and reception of data over the Ethernet connection Note that these LEDs can be...

Page 7: ...rted by clicking on Start Run if you have Windows 95 98 NT 2000 and the TCP IP client has been installed For a SEM with an IP address of 192 168 0 254 enter the following information in the dialog box...

Page 8: ...back the time it took to the save the information Reset the SEM by typing reset CR The SEM can also be reset by cycling power Whenever a reset is executed on the SEM the telnet session will be lost It...

Page 9: ...mote radio When a master SEM is powered on it becomes active immediately even if no slave SEMs are detected It will attempt to send packets addressed to devices that it thinks are not on its local net...

Page 10: ...s the better approach is to pick the hop duration to maximize data throughput without unnecessarily penalizing latency The maximum number of bytes that can be transmitted on a single hop by either a m...

Page 11: ...vices not on its subnet To display the routing table use the route list command There will always be one entry in the routing table that corresponds to the IP address in the SEM For most applications...

Page 12: ...sing the route command See the previous section for details of the route command If an IP address has previously been entered into the SEM but a DHCP server is to be used to assign an IP address it wi...

Page 13: ...Adds IP address and netmask to route list Deletes IP address from route list Lists route IP addresses socks Displays network socket information arp Manipulates the address resolution procedure table T...

Page 14: ...up override Displays synchronization settings Sets SEM as sync slave Sets synchronization mode to use RJ 11 wire ports bridge Selects filtering mode and sets master slave status filter disable turns f...

Page 15: ...rks The default mode is the sync OFF Sync is enabled by selecting a synchronization method ether and wire are mutually exclusive commands and set the synchronization to occur over the Ethernet or over...

Page 16: ...mands Most commands that require a parameter also have a help mode that displays the help screen for that command reset Resets the SEM and loads saved parameters into active memory Also causes the SEM...

Page 17: ...EM Command Description help Displays command list banner Displays power on banner for the radio in the SEM defaults Resets the radio parameters to the factory shipped values maxremotes 0 5 Displays va...

Page 18: ...ptimization parameter should be set in the remote SEMs This parameter is set using the radio a param command with dx as the sub command The dx sub command has a single argument that is a hexadecimal v...

Page 19: ...prompt type radio a param dx 04 CR Save this value by issuing the save command save CR The dx value will take effect immediately It is not necessary to issue a reset command Note that it is possible...

Page 20: ...equency hopping up to 64 user selectable hopping patterns Frequency Range 2400MHz to 2483 5MHz Operating Voltage Range 7VDC to 26VDC Enclosure Ruggedized Aluminum Dimensions 201 x 144 x 53 mm 7 9 x 5...

Page 21: ...router make sure that the correct address has been entered in the routing table The SEM does not respond through the Configuration Port Check that a straight through serial cable is being used if con...

Page 22: ...to the goods such as but not limited to power failure No suit or action shall be brought against Seller more than twelve 12 months after the related cause of action has occurred Buyer has not relied...

Reviews: