background image

Wallbox eNext Series

INSTALLATION GUIDE

(M255A01-03-20A)

Summary of Contents for Wallbox eNext M-C1

Page 1: ...Wallbox eNext Series INSTALLATION GUIDE M255A01 03 20A ...

Page 2: ...TOR SA on its web site supplies its customers with the latest versions of the de vice specifications and the most updated manuals www circutor com Disclaimer Revision log Date Revision Description 05 19 M255A01 03 19A Initial Version 11 19 M255A01 03 19B Changes in the following sections 1 2 3 4 5 5 A 5 B 5 C 5 E 5 F 5 G 5 H 5 I 5 J 6 02 20 M255A01 03 20A Changes in the following sections 6 ...

Page 3: ...tice No part of this manual can be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties at hat may result fro...

Page 4: ...Wallbox eNext Installation guide 4 ...

Page 5: ...ext 5 1 So hello 6 2 Before the installation 8 3 Overview 12 4 Dimensions 14 5 Installation 16 A Requirements 17 B Opening 18 C Positioning 19 D Fixing 20 E Wiring 21 F CirBEON 23 G DC current leakage detector 24 H Welded contactor detector 24 I Remote control function 25 J Closing 26 6 Technical Data 28 Need help 31 Guarantee 31 ...

Page 6: ...Wallbox eNext Installation guide 6 1 ...

Page 7: ... electrical risk while the operations are carried out within the unit Unit must be disconnected from any power source during commissioning ATTENTION Indicates that the damage to property can occur if appropriate precautions are not taken So hello THE FOLLOWING SYMBOLS ARE USED FOR IMPORTANT SAFETY INFORMATION IN THIS DOCUMENT Complies with IEC 61851 Electric vehicle conductive charging system IEC ...

Page 8: ...o forget especially when you are showing some electrical part pointing with metallic pencil Enclose all electric contacts and conductors so that no one can accidentally come into contact When it is necessary to handle equipment that is plugged in be sure hands are dry and when possible wear nonconductive gloves protective clothes and shoes with insulated soles If it is safe to do so work with only...

Page 9: ...nty will be void Comply strictly with electrical safety regulations according to your country Do not use any adapter except those approved by the EV manufacturer Do not make repairs or manipulations with the unit energised Only trained and qualified personnel should have access to low voltage electrical parts inside the unit Check the installation annually by qualified technician Remove from servi...

Page 10: ... of the installation have to be aligned with the local and national rules The selectivity of the protections has to be guaranteed at all times 2 POWER SUPPLY LINE DIMENSIONING The dimensioning of the input power supply line of the Charge Point must be checked by a qualified electrician Note that several factors such as cable length between distribution board and Charge Point maximum output current...

Page 11: ...Wallbox eNext Installation guide 11 ...

Page 12: ...Wallbox eNext Installation guide 12 3 What s included Charge Point Installation Guide Installation Guide 2 5 mm Allen wrench Identification label ...

Page 13: ...Wallbox eNext Installation guide 13 Overview 1 Beacon lights 2 Cable glands 3 Plugs 1 4 Wall support holes 5 Closing box holes 1 Plugs may vary depending on the model 1 2 3 5 2 4 4 4 5 ...

Page 14: ...Wallbox eNext Installation guide 14 4 Measures in mm 39 335 315 200 335 ...

Page 15: ...Wallbox eNext Installation guide 15 Dimensions 168 105 62 5 52 5 20 2 39 5 255 20 5 62 5 52 5 34 34 230 2 This measurement may vary ...

Page 16: ...d on a wall This system has been tested on a concrete wall to be securely fixed in such conditions is recommended to use 3 x Inox A2 wall screws DIN 7982 Ø4 8x3 3 x plastic anchors 6x40 or 8x40 If the wall surface has different properties the screws and plastic anchors must be defined by a qualified installer Screw driver Driller Ratchet 3 2 5mm Allen 3 Ratchet tool can be used to open close the c...

Page 17: ...Charge Point shall be installed on a wall or on CIRCUTOR accessories When installing the unit some space shall be reserved for usability maintenance and safety reasons The picture below shows the recommended minimum distances If the recommendations are not followed as described CIRCUTOR will reject all responsibility and the warranty will be void ...

Page 18: ...t Installation guide 18 B Opening Open the Wallbox using allen wrench 2 5mm Allen wrench Use the ratchet tool to open close at difficult access case Screw DIN 7380 2 M4x14 INOX Sealing washer DIN 7712 4 8 14MM INOX ...

Page 19: ...Wallbox eNext Installation guide 19 C Positioning Make the holes Tap drill M 6 8 Dimensions in mm 1100 255 230 115 ...

Page 20: ...Wallbox eNext Installation guide 20 D Fixing Place the unit on the previous pierced points and fix it with screws ...

Page 21: ...ing current not exceeding 30 mA For AC fault current RCD s protecting that connecting points shall be at least type A RCD s shall disconnect all live conductors DC fault current shall be mesured by a RCD type B or a appropriate equipment that ensures the disconnection of the supply in case of DC fault current above 6 mA MCB s Miniature circuit breaker Standards IEC 60898 1 IEC 60947 2 or IEC 61009...

Page 22: ... Phase connect L1 and N Do not forget to connect the ground cable to the ground terminal Terminal block maximum cross section 10mm2 Make sure all screws are securely tightened at 4 5 Nm S Type of cable allowed by the terminal block Copper Cu L N PE Protections L1 L2 L3 N PE Protections External electric protections should be placed upstreams as shown below ...

Page 23: ...BEON manages the remaining current for the EV Charge Point avoiding any tripping on the Main Circuit CirBEON is connected downstream of the main power switch and upstream of the main loads Signal cable has to do two loops into the snap ferrite CirBEON is only available on single phase charge points BOR1 BOR4 A B SNAP FERRITE 2S2 2S1 1S2 1S1 CirBEON For further information please refer to the eNext...

Page 24: ...The detector sends a signal to the Charge Point main PCB which stops the charge transaction by opening the inner relays This error is notified by 6 blinking red lights In order to restart the charge transaction unplug the EV When the beacon lights turn back to green and it is possible to start another charge transaction Three phase power supply The detector sends a signal to a trip coil that trips...

Page 25: ...elow You must remove the jumper to use this function BOR1 BOR4 JUMPER DISABLED ENABLED NO JUMPER BOR1 BOR4 Do not remove the jumper if remote control function is not required otherwise the charge transaction process cannot start When the jumper is removed a device outside of the Charge Point should control the charge transaction This device should close the contact START to allow the charge transa...

Page 26: ... WITH THE WIRES Before closing the unit keep in mind that all cables should remain inside 3 CHECK THE PLUGS Plugs should be in good condition before starting the unit 4 ELECTRICAL PROTECTIONS If the unit includes electrical protections rearm all of them 5 CLOSING Place the sealing washers on the screws and then place both in the Charge Point to close it Do not thight the screws yet 6 CHECK THE BEA...

Page 27: ... crosswise in the sequence shown below As a guideline the recommended assembly torque is 0 8 1Nm 9 OPERATION Check that no abnormal noise appears while the unit is charging 10 PREVENTIVE MAINTENANCE It is recommended to perform one preventive maintenance per year 1 5 2 3 4 ...

Page 28: ...age detector MCB RCBO with shunt trip is required to open the circuit RCBO RCD Type A MCB includes shunt trip Overvoltage protection 6 Transient surge protector IEC 61643 1 Class I GENERAL DATA Wireless communication Bluetooth v4 2 BLE ENVIRONMENTAL CONDITIONS Operating temperature 5ºC 45ºC Operating temperature with Low temperature kit 4 30ºC 45ºC Storage temperature 40ºC 60ºC Operating humidity ...

Page 29: ...ng on the model some components may vary 5 This is the minimum cable cross section recommended for the maximum AC input current The final cross section must be calculated by a qualified technician taking into account the specific conditions of installation 6 Optional Continuation MECHANICAL DATA Connectors 4 Shutter Type 2 Socket Type 1 Cable Type 2 Cable 7 IK8 in some components appended to the b...

Page 30: ...Wallbox eNext Installation guide 30 ...

Page 31: ...units has been improperly used or the storage installation and maintenance instructions listed in this manual have not been fol lowed Improper usage is defined as any operating or storage condition contrary to the national electrical code or that surpasses the limits indicated in the technical and environmental features of this manual CIRCUTOR accepts no liability due to the possible damage to the...

Page 32: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor com central circutor com ...

Reviews: