5�2�1�- RELAY MODE
This screen is used to configure the operating mode of relay 1.
ñnodE
oFF
ñ-
Use the
key to browse the different options:
oFF
, relay output 1 is disabled.
rEn
, remote control output.
Note:
This option is only available in devices with communication.
ALr
, alarm output.
To validate the data, press the
key.
Use the
and
keys to browse the configuration screens of the menu.
5�2�2�- RELAY PULSE DURATION
The alarm relay can behave in 2 different ways:
1�-
The relay is activated when the alarm is triggered and is deactivated when the alarm is de-
activated.
2�-
The relay is activated when the alarm is triggered and is deactivated after a programmed
period of time, even though the alarm condition has not been cancelled.
This screen is used to configure the programmed time, i.e., the relay pulse duration.
To make the relay operate in mode
no� 1
, program the value to
0
.
tinE
0000
ñ-
Use the
, key to modify the value of the flashing digit
When the desired value is shown on the screen, press the
key to skip the digit.
Minimum configuration value:
0 x 0.1 s
Maximum configuration value:
9999 x 0.1 s
Example:
Use program 0050 to configure a value of 5 s.
To validate the data, press the
key.
Use the
and
keys to browse the configuration screens of the menu.
-
21
Instruction Manual
DCB-72 mAdc, DCB-72 Adc
Summary of Contents for DCB-72 Adc
Page 1: ...INSTRUCTION MANUAL M208B01 03 21A DC Ammeter DCB 72 mAdc DCB 72 Adc...
Page 2: ...2 DCB 72 mAdc DCB 72 Adc Instruction Manual...
Page 31: ...9 CE CERTIFICATE 31 Instruction Manual DCB 72 mAdc DCB 72 Adc...
Page 32: ...32 DCB 72 mAdc DCB 72 Adc Instruction Manual...